TY - JOUR
T1 - Water-compatible magnetic imprinted nanoparticles served as solid-phase extraction sorbents for selective determination of trace 17beta-estradiol in environmental water samples by liquid chromatography
AU - Hao, Yi
AU - Gao, Ruixia
AU - Shi, Lu
AU - Liu, Dechun
AU - Tang, Yuhai
AU - Guo, Zengjun
N1 - Publisher Copyright:
© 2015 Elsevier B.V.
PY - 2015/5/29
Y1 - 2015/5/29
N2 - Endocrine disrupting compounds (EDCs) are a potential risk for wildlife and humans for their existence in water. The efficient extraction and clean-up steps are required before detection of low concentration levels of EDCs. In this work, a novel water-compatible magnetic molecularly imprinted nanoparticles is synthesized for the selective extraction of 17β-estradiol (E2) in environmental water samples. The preparation is carried out by introducing aldehyde groups to the surface of amino-functionalized magnetic nanoparticles through a simple one-step modification, followed by copolymerization of functional monomer gelatin and template E2 via surface imprinting technique. The gelatin with abundant active groups could not only act as functional monomer reacting with template, but also assemble covalently at the surface of magnetic nanoparticles. At the same time, gelatin would improve the water-compatibility of imprinted materials for attaining high extraction efficiency. To obtain high imprinting effect, the preparation conditions are optimized in detail using Central composite design-response surface methodology. The resultant polymers have uniform spherical shape with a shell thickness of about 8nm, stable crystalline form, and super-paramagnetic property. Meanwhile, the obtained polymers have high capacity of 12.87mgg-1 and satisfactory selectivity to template molecule. To testify the feasibility of the magnetic imprinted polymers in sample pretreatment, a method for determination of trace E2 in environmental water samples was set up by combination of solid-phase extraction (SPE) using the prepared polymers as sorbents and HPLC for rapid isolation and determination of E2. The limit of detection of proposed method is 0.04ngmL-1, the intra- and inter-day relative standard deviations (RSDs) are less than 4.6% and 5.7%, respectively. The recoveries of E2 from environmental water samples are in the range from 88.3% to 99.1% with the RSDs less than 7.2%.
AB - Endocrine disrupting compounds (EDCs) are a potential risk for wildlife and humans for their existence in water. The efficient extraction and clean-up steps are required before detection of low concentration levels of EDCs. In this work, a novel water-compatible magnetic molecularly imprinted nanoparticles is synthesized for the selective extraction of 17β-estradiol (E2) in environmental water samples. The preparation is carried out by introducing aldehyde groups to the surface of amino-functionalized magnetic nanoparticles through a simple one-step modification, followed by copolymerization of functional monomer gelatin and template E2 via surface imprinting technique. The gelatin with abundant active groups could not only act as functional monomer reacting with template, but also assemble covalently at the surface of magnetic nanoparticles. At the same time, gelatin would improve the water-compatibility of imprinted materials for attaining high extraction efficiency. To obtain high imprinting effect, the preparation conditions are optimized in detail using Central composite design-response surface methodology. The resultant polymers have uniform spherical shape with a shell thickness of about 8nm, stable crystalline form, and super-paramagnetic property. Meanwhile, the obtained polymers have high capacity of 12.87mgg-1 and satisfactory selectivity to template molecule. To testify the feasibility of the magnetic imprinted polymers in sample pretreatment, a method for determination of trace E2 in environmental water samples was set up by combination of solid-phase extraction (SPE) using the prepared polymers as sorbents and HPLC for rapid isolation and determination of E2. The limit of detection of proposed method is 0.04ngmL-1, the intra- and inter-day relative standard deviations (RSDs) are less than 4.6% and 5.7%, respectively. The recoveries of E2 from environmental water samples are in the range from 88.3% to 99.1% with the RSDs less than 7.2%.
KW - Magnetic separation
KW - Solid-phase extraction
KW - Surface imprinting technique
KW - Trace detection
KW - Water compatibility
UR - https://www.scopus.com/pages/publications/84928763627
U2 - 10.1016/j.chroma.2015.03.083
DO - 10.1016/j.chroma.2015.03.083
M3 - 文章
C2 - 25890441
AN - SCOPUS:84928763627
SN - 0021-9673
VL - 1396
SP - 7
EP - 16
JO - Journal of Chromatography A
JF - Journal of Chromatography A
ER -