跳到主要导航 跳到搜索 跳到主要内容

Uniform and Complete Irreversible Electroporation on Gastric Mucosa Enabled by Sintered Silver Hydrogel

  • Zhuoqun Li
  • , Shenshen Lei
  • , Quanpeng Li
  • , Fulai Lin
  • , Jian Lv
  • , Yonghui Gong
  • , Zhuomin Ping
  • , Chengjiang Wang
  • , Yuchen Cheng
  • , Wenna Liu
  • , Dingming Zhong
  • , Yutang Li
  • , Yuhao Wang
  • , Feng Ma
  • , Aihua Shi
  • , Xiaoliang Chen
  • , Chuncai Kong
  • , Bai Sun
  • , Sihai Luo
  • , Jie Tao
  • Rongqian Wu, Hao Sun, Zheng Wu, Shuixiang He, Bowen Ji, Xinge Yu, Jinyou Shao, Fenggang Ren, Yi Lyu
  • The First Affiliated Hospital of Xi’an Jiaotong University
  • Frontier Institute of Science and Technology
  • Xi'an Jiaotong University
  • School of Physics
  • Northwestern Polytechnical University Xian
  • City University of Hong Kong

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

Irreversible electroporation is a promising nonthermal ablation for gastric mucosa, but nonconformal contact between the electrode and the rough surface of the gastric mucosa causes an inhomogeneous distribution of the high-voltage electric field. Here, we enhanced gap filling and substantially reduced distortion of the delivered high-voltage electric field by fabricating a soft, highly conductive sintered silver hydrogel as the bioelectronic tissue interface, thereby achieving uniform and complete irreversible electroporation. The sintering reaction was initiated by Cl− and H+, which can work synergistically to partially eliminate the insulating surfactant on silver flakes, facilitating a sintering reaction through the dynamic redeposition of silver nanoparticles on silver flakes. Via a room-temperature sintering process, the conductivity of the hydrogel was promoted from below 1 to >104 S/m at a low silver flake loading (4 vol%), and the mechanical property was still kept at a low Young’s modulus (91 kPa), even after swelling from digestive juices. In vitro experiments demonstrated that ablation uniformity improved by up to 86%, with the ablation area increasing by 30% to 52% and a maximum depth of 5.39 mm. Preclinical validation using porcine models demonstrated uniform, complete gastric mucosal ablation, reaching a depth of 2.50 mm, extending through the muscularis mucosae and leaving no residual cells.This sintered silver hydrogel-enhanced irreversible electroporation addresses key challenges and reinforces its potential as a reliable, advanced treatment for gastrointestinal lesions.

源语言英语
期刊论文编号0697
期刊Cyborg and Bionic Systems
卷7
DOI
出版状态已出版 - 1月 2026

学术指纹

探究 'Uniform and Complete Irreversible Electroporation on Gastric Mucosa Enabled by Sintered Silver Hydrogel' 的科研主题。它们共同构成独一无二的学术指纹。

引用此