跳到主要导航 跳到搜索 跳到主要内容

Unified-distribution residual diffusion model for cross-scanner generalizable low-dose CT denoising

  • Siman Huang
  • , Siyuan Ma
  • , Mingqiang Meng
  • , Yujian Zhang
  • , Haotao Jiang
  • , Jing Huang
  • , Yongbo Wang
  • , Zhaoying Bian
  • , Jianhua Ma
  • Guangdong Provincial Key Laboratory of Medical Image Processing
  • Southern Medical University
  • Department of Artificial Intelligence
  • Guilin University of Electronic Technology
  • Key Laboratory of Biomedical Information Engineering of Ministry of Education
  • Key Lab of the Ministry of Education for Process Control and Efficiency Egineering
  • Research Center for Intelligent Medical Equipment and Devices
  • Xi'an Jiaotong University

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

Objective.The growing adoption of multi-center diagnostic and treatment protocols has heightened the demand for consistent image quality across Computed tomography (CT) devices, yet scanner-specific variations in image characteristics pose a significant challenge. Recently, deep learning-based low-dose CT (LDCT) reconstruction algorithms have been widely developed and successfully deployed in commercial clinical systems. However, existing methods for cross-scanner LDCT imaging suffer from inadequate alignment of data distributions across different scanners, which constrains their generalization performance. This study aims to propose a single model for cross-scanner LDCT image denoising.Approach.We propose a unified-distribution residual diffusion model (UDRDiff) for generalizable LDCT image denoising across diverse scanners. Specifically, we design a unified-distribution degeneration operator to progressively map cross-scanner LDCT data into a shared latent distribution by incorporating an input-suppression term, effectively mitigating inter-scanner discrepancies. To enhance the interpretability of the forward diffusion process, we introduce a residual diffusion mechanism that establishes a deterministic degradation process from normal-dose CT to LDCT, which can clearly guide the reverse image restoration process and significantly accelerate the sampling process.Main results.We extensively validated our method on datasets from four scanners, covering two manufacturers and two anatomical regions. Experimental results demonstrate that our method outperforms existing approaches across all test scenarios. Taking two representative test sets as examples: on the Scanner 1 (abdominal images) dataset, our method improves peak signal-to-noise ratio (PSNR) from 43.0765 dB to 43.5324 dB and structural similarity index (SSIM) from 0.9634 to 0.9660; on the Scanner 4 (head images) dataset, PSNR improves from 44.3582 dB to 45.9250 dB and SSIM from 0.9545 to 0.9744. These results sufficiently validate the effectiveness and generalization capability of our method across different scanners and anatomical regions.Significance.UDRDiff effectively addresses the data distribution alignment problem in cross-scanner LDCT denoising, thereby enhancing model generalizability under multi-center, multi-scanning conditions, and provides a feasible path for cross-scanner denoising of clinical LDCT images.

源语言英语
期刊Physics in medicine and biology
卷71
期17
DOI
出版状态已出版 - 2 9月 2026

学术指纹

探究 'Unified-distribution residual diffusion model for cross-scanner generalizable low-dose CT denoising' 的科研主题。它们共同构成独一无二的学术指纹。

引用此