T1 - Ultrasound-assisted enhancement of heat transfer in immersed coil heat exchangers
T2 - Effects of acoustic intensity and ambient fluid properties
AU - Lin, Weixiang
AU - Xiao, Juan
AU - Su, Gangchuan
AU - Wang, Simin
AU - Wen, Jian
N1 - Publisher Copyright:
© 2021 Elsevier Ltd
PY - 2021/12
Y1 - 2021/12
N2 - Ultrasound, as the considerable field energy source, has a significant effect on heat transfer enhancement. Although there has been deeply researched on the utilization of ultrasound in heat exchangers, the ambient environment conditions are usually ignored. In this paper, controlling vibratory surface by user defined function, the heat transfer enhancement induced by ultrasound is numerically studied in immersed coil heat exchangers, and effects of acoustic intensity, ambient pressure and ambient fluid flow velocity on the heat transfer enhancement are investigated. The results show the heat transfer enhancement factor ηh reaches to 24.26% after ultrasonic treatment for 0.005 s. When the vibratory amplitude increases from 20 μm to 35 μm, ηh raises from 15.67% to 26.71%. With an increase of the ambient pressure from 0.1 MPa to 1.0 MPa, ηh changes from 24.26% to 48.43%. While the inlet flow velocity decreases from 1.0 m/s to 0.1 m/s, ηh varies from 1.76% to 39.01%. This research based on immersed coil heat exchangers has evaluated the influence of acoustic intensity and ambient fluid properties on acoustic streaming and acoustic cavitation, which provides with a guidance in the utilization of ultrasound in heat exchangers.
AB - Ultrasound, as the considerable field energy source, has a significant effect on heat transfer enhancement. Although there has been deeply researched on the utilization of ultrasound in heat exchangers, the ambient environment conditions are usually ignored. In this paper, controlling vibratory surface by user defined function, the heat transfer enhancement induced by ultrasound is numerically studied in immersed coil heat exchangers, and effects of acoustic intensity, ambient pressure and ambient fluid flow velocity on the heat transfer enhancement are investigated. The results show the heat transfer enhancement factor ηh reaches to 24.26% after ultrasonic treatment for 0.005 s. When the vibratory amplitude increases from 20 μm to 35 μm, ηh raises from 15.67% to 26.71%. With an increase of the ambient pressure from 0.1 MPa to 1.0 MPa, ηh changes from 24.26% to 48.43%. While the inlet flow velocity decreases from 1.0 m/s to 0.1 m/s, ηh varies from 1.76% to 39.01%. This research based on immersed coil heat exchangers has evaluated the influence of acoustic intensity and ambient fluid properties on acoustic streaming and acoustic cavitation, which provides with a guidance in the utilization of ultrasound in heat exchangers.
KW - Acoustic phenomena
KW - Heat transfer enhancement
KW - Immersed coil heat exchanger
KW - Ultrasound
UR - https://www.scopus.com/pages/publications/85118899455
U2 - 10.1016/j.icheatmasstransfer.2021.105735
DO - 10.1016/j.icheatmasstransfer.2021.105735
M3 - 文章
AN - SCOPUS:85118899455
SN - 0735-1933
VL - 129
JO - International Communications in Heat and Mass Transfer
JF - International Communications in Heat and Mass Transfer
M1 - 105735
ER -