跳到主要导航 跳到搜索 跳到主要内容

Ultrasonic wireless communication technology in reactor containment

  • North China Electric Power University
  • Northwest Institute of Nuclear Technology

科研成果: 期刊稿件文章同行评审

3 引用 (Scopus)

摘要

In order to solve the problem that the traditional wireless sensor signal can't convey data from one side of reactor containment to the other side, an ultrasonic through-wall communication system is designed that ultrasonic waves are used to send data across reactor containment. The transmitting unit of ultrasonic through-wall communication system loads data signal on ultrasonic waves at 40 kHz. Ultrasonic communication unit transmits signal received from transmitting unit through the containment vessel to the receiving unit via ultrasonic transducer. Receiving unit through three-stage amplification, detection, filtering, comparison circuit, finally realizes convey data from inside of reactor containment to outside. System under the working condition of simulated containment test, the test results show that the signal can be low power consumption, stable transmission, and the bit error rate is lower than 10-6.

源语言英语
页(从-至)10-14
页数5
期刊Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology
36
1
出版状态已出版 - 20 1月 2016
已对外发布

学术指纹

探究 'Ultrasonic wireless communication technology in reactor containment' 的科研主题。它们共同构成独一无二的指纹。

引用此