摘要
In order to improve the distribution uniformity of two-phase flow in plate-fin heat exchanger, the two-phase flow distribution performance in the heat exchanger before and after configuration improvement was experimentally studied. The experimental results indicate that the maldistribution of two-phase flow is very serious in conventional heat exchanger used in industry due to the improper header configuration. The two-phase flow distribution is more complex and nonuniform than that of single-phase flow for the interaction of two-phase flow. The improved header with perforated baffle can effectively improve the uniformity of two-phase flow distribution. The fluid near the center part decreases and the flow rate near the boundary increases accordingly. The coefficients of nonuniformity of two-phase flow distribution all decrease compared with that of conventional heat exchanger. And the stability of two-phase flow distribution in the heat exchanger is also enhanced, which is not affected by Reynolds number.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 26-29 |
| 页数 | 4 |
| 期刊 | Huaxue Gongcheng/Chemical Engineering (China) |
| 卷 | 38 |
| 期 | 12 |
| 出版状态 | 已出版 - 12月 2010 |