跳到主要导航 跳到搜索 跳到主要内容

Three-year follow up of biodegradable polymer cobalt-chromium sirolimus-eluting stent (EXCROSSAL) in treating de novo coronary artery disease: Pooled analysis of CREDIT II and CREDIT III trials

  • Geng Wang
  • , Genshan Ma
  • , Ling Tao
  • , Zuyi Yuan
  • , Huiliang Liu
  • , Xinqun Hu
  • , Qian Tong
  • , Zaixin Yu
  • , Xuchen Zhou
  • , Yaling Han
  • Shenyang General Hospital of PLA
  • Zhongda Hospital Southeast University
  • Air Force Medical University
  • The First Affiliated Hospital of Xi’an Jiaotong University
  • General Hospital of People's Liberation Army
  • Central South University
  • Jilin University
  • Dalian Medical University

科研成果: 期刊稿件文章同行评审

4 引用 (Scopus)

摘要

Objectives: To analyze the 3-year outcomes of the biodegradable polymer cobalt-chromium sirolimus-eluting stent (EXCROSSAL) in CREDIT II AND III TRIALS. Background: Though approved by CFDA, the long-term safety and efficacy of EXCROSSAL is still unknown. Methods: CREDIT II was a randomized trial comparing the EXCROSSAL versus EXCEL stents in patients with up to two de novo coronary lesions, and CREDIT III was a prospective, single-arm study evaluating the efficacy and safety of EXCROSSAL in broad types of de novo coronary artery lesions. We pooled the 3-year follow-up data of the EXCROSSAL arm of the CREDIT II and CREDIT III Trials. The primary outcome was 3-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinically indicated target lesion revascularization (CI-TLR). The patient-oriented composite endpoint (PoCE) (all-cause death, all MI, or any revascularization) and stent thrombosis (ST) were also analyzed. Results: A total of 833 patients were included in this study. The incidence of TLF and PoCE in the 3-year follow-up were 7.6% and 12.5%, respectively. ST occurred in 0.6% of patients. In the subgroup analyses, TLF was significantly higher in small target vessels, multi-lesion PCI, and multi-vessel disease. Conclusions: The 3-year follow-up analysis confirmed low rates of TLF and ST in EXCROSSAL, which is similar to the most widely used new generation durable polymer drug-eluting stent.

源语言英语
页(从-至)565-571
页数7
期刊Catheterization and Cardiovascular Interventions
95
S1
DOI
出版状态已出版 - 1 2月 2020
已对外发布

学术指纹

探究 'Three-year follow up of biodegradable polymer cobalt-chromium sirolimus-eluting stent (EXCROSSAL) in treating de novo coronary artery disease: Pooled analysis of CREDIT II and CREDIT III trials' 的科研主题。它们共同构成独一无二的学术指纹。

引用此