TY - JOUR
T1 - Three-year follow up of biodegradable polymer cobalt-chromium sirolimus-eluting stent (EXCROSSAL) in treating de novo coronary artery disease
T2 - Pooled analysis of CREDIT II and CREDIT III trials
AU - Wang, Geng
AU - Ma, Genshan
AU - Tao, Ling
AU - Yuan, Zuyi
AU - Liu, Huiliang
AU - Hu, Xinqun
AU - Tong, Qian
AU - Yu, Zaixin
AU - Zhou, Xuchen
AU - Han, Yaling
N1 - Publisher Copyright:
© 2020 Wiley Periodicals, Inc.
PY - 2020/2/1
Y1 - 2020/2/1
N2 - Objectives: To analyze the 3-year outcomes of the biodegradable polymer cobalt-chromium sirolimus-eluting stent (EXCROSSAL) in CREDIT II AND III TRIALS. Background: Though approved by CFDA, the long-term safety and efficacy of EXCROSSAL is still unknown. Methods: CREDIT II was a randomized trial comparing the EXCROSSAL versus EXCEL stents in patients with up to two de novo coronary lesions, and CREDIT III was a prospective, single-arm study evaluating the efficacy and safety of EXCROSSAL in broad types of de novo coronary artery lesions. We pooled the 3-year follow-up data of the EXCROSSAL arm of the CREDIT II and CREDIT III Trials. The primary outcome was 3-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinically indicated target lesion revascularization (CI-TLR). The patient-oriented composite endpoint (PoCE) (all-cause death, all MI, or any revascularization) and stent thrombosis (ST) were also analyzed. Results: A total of 833 patients were included in this study. The incidence of TLF and PoCE in the 3-year follow-up were 7.6% and 12.5%, respectively. ST occurred in 0.6% of patients. In the subgroup analyses, TLF was significantly higher in small target vessels, multi-lesion PCI, and multi-vessel disease. Conclusions: The 3-year follow-up analysis confirmed low rates of TLF and ST in EXCROSSAL, which is similar to the most widely used new generation durable polymer drug-eluting stent.
AB - Objectives: To analyze the 3-year outcomes of the biodegradable polymer cobalt-chromium sirolimus-eluting stent (EXCROSSAL) in CREDIT II AND III TRIALS. Background: Though approved by CFDA, the long-term safety and efficacy of EXCROSSAL is still unknown. Methods: CREDIT II was a randomized trial comparing the EXCROSSAL versus EXCEL stents in patients with up to two de novo coronary lesions, and CREDIT III was a prospective, single-arm study evaluating the efficacy and safety of EXCROSSAL in broad types of de novo coronary artery lesions. We pooled the 3-year follow-up data of the EXCROSSAL arm of the CREDIT II and CREDIT III Trials. The primary outcome was 3-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinically indicated target lesion revascularization (CI-TLR). The patient-oriented composite endpoint (PoCE) (all-cause death, all MI, or any revascularization) and stent thrombosis (ST) were also analyzed. Results: A total of 833 patients were included in this study. The incidence of TLF and PoCE in the 3-year follow-up were 7.6% and 12.5%, respectively. ST occurred in 0.6% of patients. In the subgroup analyses, TLF was significantly higher in small target vessels, multi-lesion PCI, and multi-vessel disease. Conclusions: The 3-year follow-up analysis confirmed low rates of TLF and ST in EXCROSSAL, which is similar to the most widely used new generation durable polymer drug-eluting stent.
KW - biodegradable polymer drug-eluting stent
KW - coronary artery disease
KW - percutaneous coronary intervention
UR - https://www.scopus.com/pages/publications/85078237130
U2 - 10.1002/ccd.28713
DO - 10.1002/ccd.28713
M3 - 文章
C2 - 31944543
AN - SCOPUS:85078237130
SN - 1522-1946
VL - 95
SP - 565
EP - 571
JO - Catheterization and Cardiovascular Interventions
JF - Catheterization and Cardiovascular Interventions
IS - S1
ER -