跳到主要导航 跳到搜索 跳到主要内容

Thermodynamic performance analysis of steam power plants during deep peak shaving processes: Integrating a novel top turbine system in ultra-low loads

  • Xi'an Jiaotong University
  • Thermal Power Research Institute
  • Huadian Electric Power Research Institute Co., Ltd.

科研成果: 期刊稿件文章同行评审

7 引用 (Scopus)

摘要

High-penetration of renewable energy with intermittent nature poses great challenges to safety and stability of the power system. Steam power plants (SPPs), as the main regulation resource for operational flexibility, are frequently required to operate at ultra-low loads (lower than 30 % load) to meet grid requirements, which results in thermal efficiency reduction, higher generation costs, and increased greenhouse gas emissions. To address these problems, a novel top turbine system integrated into SPPs was proposed, and corresponding models were developed to evaluate system performance at all loads, especially for the ultra-low loads. The results reveal that integrating the top turbine system can enhance power generation efficiency at ultra-low loads, and the lower the design flow rate of the top turbine, the more pronounced the efficiency improvement. For a 350 MW supercritical SPP, to enhance efficiency at 20 % load, the optimized high-pressure top turbine (HPTT) design steam flow rate, inlet, and outlet pressures are 90 kg s−1, 24.2 MPa, and 9.79 MPa, respectively. Following these optimizations, power generation efficiency increases from 30.6 % to 35.2 %, accompanied by rises in live steam pressure of 10.28 MPa, reheat steam pressure of 1.74 MPa, and feedwater temperature of 78.2 °C.

源语言英语
期刊论文编号134425
期刊Energy
315
DOI
出版状态已出版 - 15 1月 2025

联合国可持续发展目标

此成果有助于实现下列可持续发展目标:

  1. 可持续发展目标 7 - 经济适用的清洁能源
    可持续发展目标 7 经济适用的清洁能源

学术指纹

探究 'Thermodynamic performance analysis of steam power plants during deep peak shaving processes: Integrating a novel top turbine system in ultra-low loads' 的科研主题。它们共同构成独一无二的学术指纹。

引用此