TY - JOUR
T1 - Thermodynamic and economic analyses of a parabolic trough concentrating solar power plant under off-design conditions
AU - Wang, Anming
AU - Han, Xiaoqu
AU - Liu, Ming
AU - Yan, Junjie
AU - Liu, Jiping
N1 - Publisher Copyright:
© 2019 Elsevier Ltd
PY - 2019/6/25
Y1 - 2019/6/25
N2 - As concentrating solar power technologies progressively move to maturity, large-scale concentrating solar power plants have elicited increasing attention. The thermodynamic simulation and economic analyses of a 50 MW parabolic trough concentrating solar power plant in northwest China were conducted in the present work. The effects of meteorological conditions, including direct normal irradiance and ambient temperature, on the off-design performances were investigated by simulation calculations. Furthermore, economic and sensitive analyses were conducted based on the annual simulation. Results show that the back-pressure of air-cooled condenser fluctuated with both ambient temperature and power generation. The power generation of summer and autumn days would decrease by 0.53–1.38 MW for the rise of condenser back-pressure. The clouds mainly affected the molten salt level of hot tank in thermal energy storage. In the economic analysis, with the decrease of the feed-in tariff from 16.6 ₵/kWh to 8.6 ₵/kWh, the maximum total net income dropped from 6.65 M$ to 2.43 M$. The optimal design condenser back-pressure rose from 5.0 kPa to 5.5 kPa. Moreover, the optimal design back-pressure of air-cooled condenser was not sensitive to the cloud effect in certain range, but the total net income had a sharp drop from 7.37 M$ to 4.95 M$.
AB - As concentrating solar power technologies progressively move to maturity, large-scale concentrating solar power plants have elicited increasing attention. The thermodynamic simulation and economic analyses of a 50 MW parabolic trough concentrating solar power plant in northwest China were conducted in the present work. The effects of meteorological conditions, including direct normal irradiance and ambient temperature, on the off-design performances were investigated by simulation calculations. Furthermore, economic and sensitive analyses were conducted based on the annual simulation. Results show that the back-pressure of air-cooled condenser fluctuated with both ambient temperature and power generation. The power generation of summer and autumn days would decrease by 0.53–1.38 MW for the rise of condenser back-pressure. The clouds mainly affected the molten salt level of hot tank in thermal energy storage. In the economic analysis, with the decrease of the feed-in tariff from 16.6 ₵/kWh to 8.6 ₵/kWh, the maximum total net income dropped from 6.65 M$ to 2.43 M$. The optimal design condenser back-pressure rose from 5.0 kPa to 5.5 kPa. Moreover, the optimal design back-pressure of air-cooled condenser was not sensitive to the cloud effect in certain range, but the total net income had a sharp drop from 7.37 M$ to 4.95 M$.
KW - Cloud effect
KW - Off-design conditions
KW - Parabolic trough concentrating solar power
KW - Thermodynamic and economic analyses
UR - https://www.scopus.com/pages/publications/85064528870
U2 - 10.1016/j.applthermaleng.2019.04.062
DO - 10.1016/j.applthermaleng.2019.04.062
M3 - 文章
AN - SCOPUS:85064528870
SN - 1359-4311
VL - 156
SP - 340
EP - 350
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
ER -