T1 - Thermo-economic optimization on the waste heat recovery system of SCO2coal-fired power plants
AU - Sun, Ruiqiang
AU - Yang, Kaixuang
AU - Liu, Ming
AU - Yan, Junjie
N1 - Publisher Copyright:
Copyright © 2020 ASME.
PY - 2020
Y1 - 2020
N2 - The temperature of SCO2 fed to the boiler in SCO2 coalfired power plants is relatively high, ∼500 °C. It leads to high boiler exhaust temperature, which is ∼120 °C according to previous studies. Waste heat recovery from low temperature fluegas in SCO2 coal-fired power plants is a key issue to be addressed to enhance power plant efficiency and electrostatic precipitator performance. Therefore, systems of waste heat recovery from low-temperature fluegas were proposed in this study. To evaluate the economic performances of the proposed systems and obtain the best system configurations, economic and thermodynamic models were developed. Moreover, multiparameter optimization model based on Genetic Algorithm was developed. The waste heat recovery system is proposed and optimized by considering coupling and matching of the air preheating process, heat regenerative process and fluegas cooling process. With a 1000MW SCO2 coal-fired power plant as the reference case, thermodynamic and economic analyses were carried out. Results show that when the low temperature economizer is integrated together with the main compressor intercooling and flue bypass ahead the air-preheater, the temperature of exhaust fluegas can be decreased to ∼95 °C and the power plant efficiency can be enhanced by 1.39%-pts compared with basic system. Through the economic model analysis, the system levelized cost of electricity is 0.04158 $ kW-1 h-1.
AB - The temperature of SCO2 fed to the boiler in SCO2 coalfired power plants is relatively high, ∼500 °C. It leads to high boiler exhaust temperature, which is ∼120 °C according to previous studies. Waste heat recovery from low temperature fluegas in SCO2 coal-fired power plants is a key issue to be addressed to enhance power plant efficiency and electrostatic precipitator performance. Therefore, systems of waste heat recovery from low-temperature fluegas were proposed in this study. To evaluate the economic performances of the proposed systems and obtain the best system configurations, economic and thermodynamic models were developed. Moreover, multiparameter optimization model based on Genetic Algorithm was developed. The waste heat recovery system is proposed and optimized by considering coupling and matching of the air preheating process, heat regenerative process and fluegas cooling process. With a 1000MW SCO2 coal-fired power plant as the reference case, thermodynamic and economic analyses were carried out. Results show that when the low temperature economizer is integrated together with the main compressor intercooling and flue bypass ahead the air-preheater, the temperature of exhaust fluegas can be decreased to ∼95 °C and the power plant efficiency can be enhanced by 1.39%-pts compared with basic system. Through the economic model analysis, the system levelized cost of electricity is 0.04158 $ kW-1 h-1.
KW - Coal
KW - Economic optimization
KW - SCO2 cycle
KW - Thermodynamic analysis
KW - Waste heat recovery
UR - https://www.scopus.com/pages/publications/85094214289
U2 - 10.1115/POWER2020-16271
DO - 10.1115/POWER2020-16271
M3 - 会议稿件
AN - SCOPUS:85094214289
T3 - American Society of Mechanical Engineers, Power Division (Publication) POWER
BT - ASME 2020 Power Conference, POWER 2020, collocated with the 2020 International Conference on Nuclear Engineering
PB - American Society of Mechanical Engineers (ASME)
T2 - 2019 Canadian Society for Civil Engineering Annual Conference, CSCE 2019
Y2 - 12 June 2019 through 15 June 2019