跳到主要导航 跳到搜索 跳到主要内容

Thermal-hydraulic analysis of He–Xe gas mixture in 2×2 rod bundle wrapped with helical wires

  • Xi'an Jiaotong University

科研成果: 期刊稿件文章同行评审

10 引用 (Scopus)

摘要

Gas-cooled space reactor, which adopts He–Xe gas mixture as working fluid, is a better choice for megawatt power generation. In this paper, thermal-hydraulic characteristics of He–Xe gas mixture in 2 × 2 rod bundle wrapped with helical wires is numerically investigated. The velocity, pressure and temperature distribution of the coolant are obtained and analyzed. The results show that the existence of helical wires forms the vortexes and changes the velocity and temperature distribution. Hot spots are found at the contact corners between helical wires and fuel rods. The highest temperature of the hot spots reach 1600K, while the mainstream temperature is less than 400K. The helical wire structure increases the friction pressure drop by 20%–50%. The effect extent varies with the pitch and the number of helical wires. The helical wire structure leads to the reduction of Nusselt number. Comparing thermal-hydraulic performance ratios (THPR) of different structures, the THPR values are all less than 1. It means that gas-cooled space reactor adopting helical wires could not strengthen the core heat removal performance. This work provides the thermal-hydraulic design basis for He–Xe gas cooled space nuclear reactor.

源语言英语
页(从-至)2534-2546
页数13
期刊Nuclear Engineering and Technology
55
7
DOI
出版状态已出版 - 7月 2023

学术指纹

探究 'Thermal-hydraulic analysis of He–Xe gas mixture in 2×2 rod bundle wrapped with helical wires' 的科研主题。它们共同构成独一无二的学术指纹。

引用此