N2 - Spindles in precision boring machines usually operate without internal cooling, and thermal error in such spindles is nonnegligible and can severely affect the end-processing quality of the machines. This study aims to investigate the effects that external cooling exerts on the thermal behavior of such spindles. A helical tube cooler is taken for external cooling. An analytical thermal resistance model for the grease-coated cooler-housing joint surface, which considers the pressured cambered-flat contact pair and rough metal surface-grease contact, is presented and validated, and a numerical thermal–fluid–solid coupling model for the cooler-spindle system is then established. An evaluation method is put forward to obtain the stability of the thermal error, which determines the boring processing accuracy and thermal equilibrium time, from experimental data. Then, the external cooling was optimally designed based on the simulation results from the numerical model. Experiments show that the designed cooler reduced the thermal equilibrium time by 47.13% and the maximum thermal error by 81.7%, and the proposed model can accurately predict the cooling effect on the spindle thermal behavior. This study not only provides a thermal error control method for the spindle but is expected to advance the theoretical basis of cooling design for complex electromechanical systems.
AB - Spindles in precision boring machines usually operate without internal cooling, and thermal error in such spindles is nonnegligible and can severely affect the end-processing quality of the machines. This study aims to investigate the effects that external cooling exerts on the thermal behavior of such spindles. A helical tube cooler is taken for external cooling. An analytical thermal resistance model for the grease-coated cooler-housing joint surface, which considers the pressured cambered-flat contact pair and rough metal surface-grease contact, is presented and validated, and a numerical thermal–fluid–solid coupling model for the cooler-spindle system is then established. An evaluation method is put forward to obtain the stability of the thermal error, which determines the boring processing accuracy and thermal equilibrium time, from experimental data. Then, the external cooling was optimally designed based on the simulation results from the numerical model. Experiments show that the designed cooler reduced the thermal equilibrium time by 47.13% and the maximum thermal error by 81.7%, and the proposed model can accurately predict the cooling effect on the spindle thermal behavior. This study not only provides a thermal error control method for the spindle but is expected to advance the theoretical basis of cooling design for complex electromechanical systems.
KW - Precision boring machine
KW - grease-coated joint
KW - helical tube
KW - thermal equilibrium
KW - thermal error stabilization
UR - https://www.scopus.com/pages/publications/85074481018
U2 - 10.1177/0954406219879720
DO - 10.1177/0954406219879720
M3 - 文章
AN - SCOPUS:85074481018
SN - 0954-4062
VL - 234
SP - 658
EP - 675
JO - Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
JF - Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
IS - 2
ER -