跳到主要导航 跳到搜索 跳到主要内容

Theoretical accuracy of anisotropic thermal conductivity determined by transient plane source method

  • Xi'an Jiaotong University

科研成果: 期刊稿件 › 文章 › 同行评审

69 引用 (Scopus)

摘要

The transient plane source (TPS) method could measure the in-plane thermal conductivity and through-plane thermal conductivity of anisotropic materials through one single test once the volumetric heat capacity is known. The practical thicknesses of the heating element and the insulation layer deviate from the plane source assumption and have an influence on the accuracy of the isotropic thermal conductivity of bulk specimen and film specimen determined experimentally. The theoretical accuracy of measured anisotropic thermal conductivities will also be affected by the practical sensor thickness. A numerical study is conducted to investigate the deviation of anisotropic thermal conductivity due to the non-compliance of the theoretical assumption of TPS method. The influence of the practical sensor thickness on the theoretical accuracy of different thermal conductivities and different anisotropic ratios is discussed. The simulation studies show that the deviation brought by the plane source assumption, i.e., with zero thickness, becomes significant for materials with high thermal conductivity (thermal diffusivity) and can be improved by employing sensor with larger radius.

源语言英语
页(从-至)1634-1644
页数11
期刊International Journal of Heat and Mass Transfer
卷108
DOI
出版状态已出版 - 2017

学术指纹

探究 'Theoretical accuracy of anisotropic thermal conductivity determined by transient plane source method' 的科研主题。它们共同构成独一无二的学术指纹。