T1 - The optimization of multi-parameter insulation diagnosis
AU - Wu, Kai
AU - Shen, Wei
AU - Meng, Yong Peng
AU - Cao, Wen
AU - Pan, Cheng
AU - Cheng, Yonghong
AU - Zhang, Xiaohong
PY - 2009
Y1 - 2009
N2 - On the basis of statistical theory, a method to quantitatively determine the reliability of multi-parameter diagnosis and to optimize the algorithm of multi-parameter diagnosis is put forward. This method is based on the statistical law, and concerns correlation between the different parameters. Moreover, as an example, the stator bar of generator (300 MW, 18 kV) is studied. 30 samples were selected from different parts of the practical stator bar of generators, and the parameters of dielectric loss, partial discharge and remaining breakdown voltage (BDV, 50 Hz) of each sample were measured. This method is applied to the estimation BDV of generator bars and the optimized multi-parameter diagnosis algorithm is determined on the basis of actual data. Sk+, tanδ and ΔC are selected as the optimal parameter group by this method. Comparing with experimental data, it shows that the quantity of parameters is not the more the better. To choose appropriate parameters for assessing insulation condition is important. In order to choose appropriate parameters, two following principles are suggested. 1) It is efficient to select the parameters which have significant correlation with estimation object, as well as to obviate those of limited correlation. 2) Correlation between parameters should be taken into account. Generally speaking, the degree of correlation between parameters is the lower the better.
AB - On the basis of statistical theory, a method to quantitatively determine the reliability of multi-parameter diagnosis and to optimize the algorithm of multi-parameter diagnosis is put forward. This method is based on the statistical law, and concerns correlation between the different parameters. Moreover, as an example, the stator bar of generator (300 MW, 18 kV) is studied. 30 samples were selected from different parts of the practical stator bar of generators, and the parameters of dielectric loss, partial discharge and remaining breakdown voltage (BDV, 50 Hz) of each sample were measured. This method is applied to the estimation BDV of generator bars and the optimized multi-parameter diagnosis algorithm is determined on the basis of actual data. Sk+, tanδ and ΔC are selected as the optimal parameter group by this method. Comparing with experimental data, it shows that the quantity of parameters is not the more the better. To choose appropriate parameters for assessing insulation condition is important. In order to choose appropriate parameters, two following principles are suggested. 1) It is efficient to select the parameters which have significant correlation with estimation object, as well as to obviate those of limited correlation. 2) Correlation between parameters should be taken into account. Generally speaking, the degree of correlation between parameters is the lower the better.
KW - Choice of parameters
KW - Insulation diagnosis
KW - Multi-parameter
UR - https://www.scopus.com/pages/publications/77949291776
U2 - 10.1109/CEIDP.2009.5377795
DO - 10.1109/CEIDP.2009.5377795
M3 - 会议稿件
AN - SCOPUS:77949291776
SN - 9781424445592
T3 - Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP
SP - 73
EP - 76
BT - CEIDP - 2009 Annual Report Conference on Electrical Insulation and Dielectric Phenomena
T2 - 2009 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, CEIDP
Y2 - 18 October 2009 through 21 October 2009
ER -