跳到主要导航 跳到搜索 跳到主要内容

Sulfuric acid deposition characteristics of H-type finned tube bank with 10 rows

  • Xi'an Jiaotong University

科研成果: 期刊稿件文章同行评审

45 引用 (Scopus)

摘要

The deposition rate and condensate mass fraction of sulfuric acid on heat exchanger surfaces play a decisive role on the local low-temperature corrosion of heat exchangers. Based on the prediction model of acid deposition, a three-dimensional numerical simulation was performed for acid deposition characteristics of H-type finned tube bank with 10 rows. The effect of six geometric parameters (spanwise tube pitch, longitudinal tube pitch, fin height, fin pitch, fin thickness and slit width) and Reynolds number are examined. It can be observed that the fin thickness and Reynolds number have the most significant effect on acid deposition. A large fin thickness will greatly increase the risks of fin corrosion, and it is not recommended for practical use. According to the calculation results, a correlation of Sh number of sulfuric acid vs fin geometries for the 10-row tube bundle is presented.

源语言英语
页(从-至)137-141
页数5
期刊International Journal of Heat and Mass Transfer
81
DOI
出版状态已出版 - 2月 2015

学术指纹

探究 'Sulfuric acid deposition characteristics of H-type finned tube bank with 10 rows' 的科研主题。它们共同构成独一无二的指纹。

引用此