跳到主要导航 跳到搜索 跳到主要内容

Study on dynamic characteristics of a 600MW ultra-supercritical double-reheat boiler

  • Xi'an Jiaotong University

科研成果: 期刊稿件会议文章同行评审

3 引用 (Scopus)

摘要

Based on the GSE software, the simulation model of an ultra-supercritical double-reheat tower boiler was established, and its reliability was checked with design data. Then, the dynamic characteristics of the ultra-supercritical double-reheat boiler were studied. Simulation results reveal the response times of different input parameters greatly vary. When stepping disturbances to the feed-coal rate, feed-water rate, and feed-water temperature, the response time under feed-water's temperature disturbance is the longest, which is about 1, 800 s. When the same input parameter disturbs, the output parameters have the same response tendency with different amplitudes. Moreover, the fiercer the disturbance is, the more greatly the parameter changes.

源语言英语
页(从-至)5257-5262
页数6
期刊Energy Procedia
158
DOI
出版状态已出版 - 2019
活动10th International Conference on Applied Energy, ICAE 2018 - Hong Kong, 中国
期限: 22 8月 201825 8月 2018