摘要
In order to improve the performance of a one-stage pulse tube cryocooler, gas mixtures are used for comparison, which have been used in other cryocoolers. A mixture of hydrogen and helium was investigated in this study. When the structure of the pulse tube is the same as mentioned in [C. Wang, P.Y. Wu, Zh.Q. Chen, Numerical modeling of an orifice pulse tube cryocooler, Cryogenics 32 (1992) 785] and the working conditions are: frequency 15 Hz, average pressure 1.1 MPa, hot end temperature 300 K and cold end temperature 80 K, it has been found that there are optimal molar percentage for the maximal cooling power and the maximal-coefficient of performance (COP) of this cryocooler.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 475-480 |
| 页数 | 6 |
| 期刊 | Cryogenics |
| 卷 | 40 |
| 期 | 7 |
| DOI | |
| 出版状态 | 已出版 - 2000 |
学术指纹
探究 'Study on a pulse tube cryocooler using gas mixture as its working fluid' 的科研主题。它们共同构成独一无二的学术指纹。引用此