跳到主要导航 跳到搜索 跳到主要内容

Study on a pulse tube cryocooler using gas mixture as its working fluid

  • Xi'an Jiaotong University

科研成果: 期刊稿件 › 文章 › 同行评审

9 引用 (Scopus)

摘要

In order to improve the performance of a one-stage pulse tube cryocooler, gas mixtures are used for comparison, which have been used in other cryocoolers. A mixture of hydrogen and helium was investigated in this study. When the structure of the pulse tube is the same as mentioned in [C. Wang, P.Y. Wu, Zh.Q. Chen, Numerical modeling of an orifice pulse tube cryocooler, Cryogenics 32 (1992) 785] and the working conditions are: frequency 15 Hz, average pressure 1.1 MPa, hot end temperature 300 K and cold end temperature 80 K, it has been found that there are optimal molar percentage for the maximal cooling power and the maximal-coefficient of performance (COP) of this cryocooler.

源语言英语
页(从-至)475-480
页数6
期刊Cryogenics
卷40
期7
DOI
出版状态已出版 - 2000