TY - JOUR
T1 - Study of individual characteristic abdominal wall thickness based on magnetic anchored surgical instruments
AU - Dong, Ding Hui
AU - Liu, Wen Yan
AU - Feng, Hai Bo
AU - Fu, Yi Li
AU - Huang, Shi
AU - Xiang, Jun Xi
AU - Lyu, Yi
N1 - Publisher Copyright:
© 2015, Chinese Medical Association. All rights reserved.
PY - 2015/1/8
Y1 - 2015/1/8
N2 - Background: Magnetic anchored surgical instruments (MASI), relying on magnetic force, can break through the limitations of the single port approach in dexterity. Individual characteristic abdominal wall thickness (ICAWT) deeply influences magnetic force that determines the safety of MASI. The purpose of this study was to research the abdominal wall characteristics in MASI applied environment to find ICAWT, and then construct an artful method to predict ICAWT, resulting in better safety and feasibility for MASI. Methods: For MASI, ICAWT is referred to the thickness of thickest point in the applied environment. We determined ICAWT through finding the thickest point in computed tomography scans. We also investigated the traits of abdominal wall thickness to discover the factor that can be used to predict ICAWT. Results: Abdominal wall at C point in the middle third lumbar vertebra plane (L3) is the thickest during chosen points. Fat layer thickness plays a more important role in abdominal wall thickness than muscle layer thickness. “BMI-ICAWT” curve was obtained based on abdominal wall thickness of C point in L3 plane, and the expression was as follow: f(x) = P1 × x2 + P2 × x + P3, where P1 = 0.03916 (0.01776, 0.06056), P2 = 1.098 (0.03197, 2.164), P3 = -18.52 (-31.64, -5.412), R-square: 0.99. Conclusions: Abdominal wall thickness of C point at L3 could be regarded as ICAWT. BMI could be a reliable predictor of ICAWT. In the light of “BMI-ICAWT” curve, we may conveniently predict ICAWT by BMI, resulting a better safety and feasibility for MASI.
AB - Background: Magnetic anchored surgical instruments (MASI), relying on magnetic force, can break through the limitations of the single port approach in dexterity. Individual characteristic abdominal wall thickness (ICAWT) deeply influences magnetic force that determines the safety of MASI. The purpose of this study was to research the abdominal wall characteristics in MASI applied environment to find ICAWT, and then construct an artful method to predict ICAWT, resulting in better safety and feasibility for MASI. Methods: For MASI, ICAWT is referred to the thickness of thickest point in the applied environment. We determined ICAWT through finding the thickest point in computed tomography scans. We also investigated the traits of abdominal wall thickness to discover the factor that can be used to predict ICAWT. Results: Abdominal wall at C point in the middle third lumbar vertebra plane (L3) is the thickest during chosen points. Fat layer thickness plays a more important role in abdominal wall thickness than muscle layer thickness. “BMI-ICAWT” curve was obtained based on abdominal wall thickness of C point in L3 plane, and the expression was as follow: f(x) = P1 × x2 + P2 × x + P3, where P1 = 0.03916 (0.01776, 0.06056), P2 = 1.098 (0.03197, 2.164), P3 = -18.52 (-31.64, -5.412), R-square: 0.99. Conclusions: Abdominal wall thickness of C point at L3 could be regarded as ICAWT. BMI could be a reliable predictor of ICAWT. In the light of “BMI-ICAWT” curve, we may conveniently predict ICAWT by BMI, resulting a better safety and feasibility for MASI.
KW - Individual characteristic abdominal wall thickness
KW - Magnetic anchored surgical instruments
KW - Minimally invasive surgery
UR - https://www.scopus.com/pages/publications/84937839634
U2 - 10.4103/0366-6999.161360
DO - 10.4103/0366-6999.161360
M3 - 文章
C2 - 26228215
AN - SCOPUS:84937839634
SN - 0366-6999
VL - 128
SP - 2040
EP - 2044
JO - Chinese Medical Journal
JF - Chinese Medical Journal
IS - 15
ER -