Study of end-to-end magnetic anastomosis technique of intrahepatic inferior vena cava in rats

  • Xinying Wang
  • , Lifei Yang
  • , Lu Ren
  • , Yong Wan
  • , Yi Lyu
  • , Shanpei Wang
  • , Qiang Lu
  • The First Affiliated Hospital of Xi’an Jiaotong University

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

Objective To develop a magnetic anastomosis device for infrahepatic inferior vena cava and verify its feasibility and safety in rat models. Methods According to the anatomical characteristics of rat inferior vena cava, a magnetic- device suitable for end-to-end anastomosis of infrahepatic inferior vena cava was designed and manufactured. The device consisted of the inner and outer rings. The inner ring was a coated neodymium-iron-boron magnetic ring, and the outer ring was made of polyetheretherketone by 3D printing. Ten fine holes are evenly distributed on the outer ring, of which 5 fine holes were used to load the fine needles, and the other 5 fine holes were mutually connected with the fine needles of the contralateral anastomosis ring during anastomosis. The outer ring was uniformly loaded with fine needles and then bonded with the inner ring to form a magnetic anastomosis complex. Bilateral ends of vessels passed through the anastomosis ring and were fixed to the fine needles, and then end-to-end vascular anastomosis was performed by mutual attraction of two magnetic anastomosis rings. Twenty SD rats were selected and received end-to-end anastomosis of infrahepatic inferior vena cava with magnetic anastomosis dcvicc. The time of vascular occlusion, postoperative survival, postoperative anastomotic patency, gross observation and histological examination of anastomotic stoma were analyzed. Results All rats successfully completed end-to-end magnetic anastomosis of the infrahepatic inferior vena cava, and the time of vascular occlusion was 4-6 min. One rat died at 10 d after operation, and the other rats survived within postoperative 2 months. The patency rates of anastomotic stoma in surviving rats at postoperative 1 d, 3 d, 1 month and 2 months were 100%, 100%, 95% and 95%, respectively. At 2 months after operation, no obvious displacement and angulation of the anastomosis device were seen. No signs of corrosion and cracking of the anastomosis rings were observed. No evident hyperplasia and edema of surrounding tissues were noted. Bilateral ends of vessels were completely healed, and no obvious stenosis or thrombosis was found at the anastomotic stoma. Histological examination showed high continuity of bilateral vascular walls of anastomotic stoma, the inner surface of anastomotic stoma was covered by endothelial cells, and no thrombus or fibrous tissue was attached. Conclusions It is safe and feasible to utilize the self-designed magnetic anastomosis device to perform end-to-end magnetic anastomosis of infrahcpatic inferior vena cava in rat models.

源语言英语
页(从-至)483-488
页数6
期刊Organ Transplantation
卷13
期4
DOI
出版状态已出版 - 1 7月 2022
已对外发布是

学术指纹

探究 'Study of end-to-end magnetic anastomosis technique of intrahepatic inferior vena cava in rats' 的科研主题。它们共同构成独一无二的学术指纹。

引用此