摘要
Density wave oscillation in a vertical up-flow pipe of two-phase natural circulation loop was studied. The oscillation curves under different conditions were obtained. By means of plurality linear regression analysis of experimental data, a stability criterion of density wave oscillation under low pressure two-phase natural circulation conditions was developed. The ranges of experimental parameters are as the following: system pressure P=0.21-1.75 MPa, mass flow rate G=345-1947 kg/m2·s, inlet subcooling δTsub=6-60 °C, heated power Q=2.3-24 kW.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 12-14, 20 |
| 期刊 | Hedongli Gongcheng/Nuclear Power Engineering |
| 卷 | 19 |
| 期 | 1 |
| 出版状态 | 已出版 - 1998 |