TY - JOUR
T1 - Spectral diagnosis of gas temperature of atmospheric pressure plasma jet in helium
AU - Chang, Zhengshi
AU - Shao, Xianjun
AU - Zhang, Zenghui
AU - Zhang, Guanjun
PY - 2013/9
Y1 - 2013/9
N2 - For atmospheric pressure plasma jets (APPJ), the gas temperature is essential for their applications. A spectral diagnosis of APPJ's gas temperature is conducted in this work. The optical emission spectra of helium APPJ are captured by using an optical spectrometer system. Then, the grating secondary spectrum of OH (A2∑+(ν'=0) → X2Π(ν″=0)) are used to diagnose the gas temperature of plasmas because the spectrum has excellent resolution. Meanwhile, the vibrational temperatures are estimated by using the vibration sequence of N2 band (SPS, the second positive system). On the basis of the method, some important conclusions were obtained. First, the spectral identifying indicates that the grating primary spectrum covers a whole wavelength range from 200 nm to 900 nm, and that the grating secondary spectrum overlaps with the primary spectrum from 400 nm to 900 nm. Second, the gas temperature (about 320 K) is close to the room temperature, while the vibrational temperature of the N2 (SPS) is about 5000 K. The trend of the two temperatures changing with the applied voltage is discussed in the end.
AB - For atmospheric pressure plasma jets (APPJ), the gas temperature is essential for their applications. A spectral diagnosis of APPJ's gas temperature is conducted in this work. The optical emission spectra of helium APPJ are captured by using an optical spectrometer system. Then, the grating secondary spectrum of OH (A2∑+(ν'=0) → X2Π(ν″=0)) are used to diagnose the gas temperature of plasmas because the spectrum has excellent resolution. Meanwhile, the vibrational temperatures are estimated by using the vibration sequence of N2 band (SPS, the second positive system). On the basis of the method, some important conclusions were obtained. First, the spectral identifying indicates that the grating primary spectrum covers a whole wavelength range from 200 nm to 900 nm, and that the grating secondary spectrum overlaps with the primary spectrum from 400 nm to 900 nm. Second, the gas temperature (about 320 K) is close to the room temperature, while the vibrational temperature of the N2 (SPS) is about 5000 K. The trend of the two temperatures changing with the applied voltage is discussed in the end.
KW - Atmospheric pressure plasmas jet
KW - Gas temperature
KW - Grating primary spectrum
KW - Grating secondary spectrum
KW - Helium
KW - Optical emission spectra
UR - https://www.scopus.com/pages/publications/84885789337
U2 - 10.3969/j.issn.1003-6520.2013.09.028
DO - 10.3969/j.issn.1003-6520.2013.09.028
M3 - 文章
AN - SCOPUS:84885789337
SN - 1003-6520
VL - 39
SP - 2260
EP - 2266
JO - Gaodianya Jishu/High Voltage Engineering
JF - Gaodianya Jishu/High Voltage Engineering
IS - 9
ER -