跳到主要导航 跳到搜索 跳到主要内容

Simulations of the source-range detector response for the fuel-loading process of the AP1000 cores

  • Xi'an Jiaotong University
  • Sanmen Nuclear Power Co. Ltd.

科研成果: 期刊稿件文章同行评审

4 引用 (Scopus)

摘要

In this paper, the ex-core source-range detector response was simulated for AP1000 cores in its fuel-loading process by using a Monte Carlo code. Firstly, the current sensitivity coefficients of the ex-core source-range detectors have been calibrated by utilizing the experiments with single fuel assembly and the primary source loaded in the core. Secondly, both relative and absolute calibration methods have been applied and analyzed for the sensitivity coefficients calibration. Thirdly, the simulation values for the ex-core source-range response with fully loaded fuel have been validated by using the actual measurement of the first AP1000 cores in the world. Fourthly, the contribution of the 238U spontaneous fission to the ex-core source-range detector response has been studied. Through the numerical simulation results, the following observations can be obtained: 1) The relative calibration method is better than the absolute calibration method, especially when the ex-core source-range response is small. 2) Compared with the measurements, the relative deviation between the simulated and the measured values is within 14% for the two AP1000 cores at Sanmen Nuclear Power Plant. 3) The intensity of 238U spontaneous fission source accounts for 15% of the total source strength in the AP1000 core Unit 1, but the maximum change of response is only 0.02 cps, which is still insignificant for the ex-core detector response simulation in PWR.

源语言英语
文章编号110995
期刊Nuclear Engineering and Design
372
DOI
出版状态已出版 - 2月 2021

学术指纹

探究 'Simulations of the source-range detector response for the fuel-loading process of the AP1000 cores' 的科研主题。它们共同构成独一无二的指纹。

引用此