摘要
The coal-fired power plants operate frequently under off-design condition because of the load fluctuations in power grids caused by the rapid spread of power generation capacity from unpredictable renewable energy sources. Dynamic models of a 660 MW supercritical unit were established with the GSE software. The models have good accuracy with the error not more than ±0.5%. In this paper, the influence of the transient process of the unit load-up on denitrification and particle removal was studied. The results show that with the increase of unit load, the denitrification efficiency increases and the particle removal efficiency decreases gradually. During the load-up process, the transient stability time of denitrification is far less than the particle removal. At the same time, the denitrification efficiency of SCR shows a sudden decrease and then a rapid increase, and the efficiency of ESP firstly increases suddenly and then decreases to stable. When the amplitude of the load-up is large, SCR is prone to overshoot, resulting in NOx excessive emission.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 1144-1149 |
| 页数 | 6 |
| 期刊 | Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics |
| 卷 | 38 |
| 期 | 6 |
| 出版状态 | 已出版 - 1 6月 2017 |
联合国可持续发展目标