跳到主要导航 跳到搜索 跳到主要内容

Short fault of bridge arm in cycloconverter for fractional frequency transmission system

  • State Grid Sichuan Research Institute
  • Xi'an Jiaotong University

科研成果: 期刊稿件文章同行评审

4 引用 (Scopus)

摘要

In a fractional frequency transmission system (FFTS), the fault characteristics are analyzed by switching property of thyristor when short-circuit fault occurs in one of the cycloconverter bridge arms. The different operation modes of the cycloconverter, i.e., the rectifier mode, the inverter mode and bridge-switching stage, are taken into consideration. The calculating method for voltage on the lower frequency side and currents on both lower frequency side and industrial frequency side are proposed, and the fault characteristics of the cycloconverter are thus quantitatively described. Analysis shows that in case of short-circuit fault, the bridge arms fail for commutating, the voltage on the low frequency side drops obviously, and the fault current on industrial frequency side gets very large. However the cycloconverter in FFTS usually works in the rectifier mode, the peak value of fault current on its industrial frequency side can be reduced by over 40%. Simulations verify the above analysis.

源语言英语
页(从-至)56-61
页数6
期刊Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University
48
2
DOI
出版状态已出版 - 2月 2014

学术指纹

探究 'Short fault of bridge arm in cycloconverter for fractional frequency transmission system' 的科研主题。它们共同构成独一无二的学术指纹。

引用此