跳到主要导航 跳到搜索 跳到主要内容

Series Arc Fault Identification for Photovoltaic System Based on Time-Domain and Time-Frequency-Domain Analysis

  • Xi'an Jiaotong University

科研成果: 期刊稿件文章同行评审

120 引用 (Scopus)

摘要

This paper aims at providing a reliable algorithm to identify photovoltaic (PV) series arc faults regardless of complex fault-like interferences. Through conducting various arc fault experiments with different PV current levels, arc gap lengths, and load types, PV series arc fault features have been understood comprehensively. To avoid unwanted nuisance tripping, fault-like conditions are analyzed to confirm the unique arc fault features. Based on the loop current signature, a greater unstable fluctuation in the time domain and extra arc noises in the time-frequency domain are chosen as identification features. By quantificational evaluations, optimal detection variables with the Hamming window and the proper time resolution have been established to achieve the best identification results. By building fusion coefficients, two variables are arithmetically fused to achieve the arc fault discovery. The algorithm could also classify fault-like into normal and adjust the threshold value dynamically to fit different normal current levels. Its validity has been verified by experimental results on the simulated platform.

源语言英语
期刊论文编号7924425
页(从-至)1105-1114
页数10
期刊IEEE Journal of Photovoltaics
7
4
DOI
出版状态已出版 - 7月 2017

联合国可持续发展目标

此成果有助于实现下列可持续发展目标:

  1. 可持续发展目标 7 - 经济适用的清洁能源
    可持续发展目标 7 经济适用的清洁能源

学术指纹

探究 'Series Arc Fault Identification for Photovoltaic System Based on Time-Domain and Time-Frequency-Domain Analysis' 的科研主题。它们共同构成独一无二的学术指纹。

引用此