The turn-table platform stirring technique has been used to improve the measurement accuracy of a reverberation chamber (RC), where half-wavelength spatial sampling on the platform is usually used as a rule of thumb. A smaller sampling distance (scaling factor) was suggested experimentally by curve fitting in a previous work. However, an analytical study of this scaling factor is still missing in the literature. By expanding the electromagnetic plane wave using the Jacobi-Anger expansion, the scaling factor is determined when the truncation error falls below certain threshold. The result is verified by measurements in a RC.