跳到主要导航 跳到搜索 跳到主要内容

Safety and Efficacy of Intravascular Lithotripsy System: A Prospective, Multicenter Clinical Trial (The VIGOUR Study)

  • Tao Chen
  • , Jiawei Zhao
  • , Yong He
  • , Chao Fang
  • , Xuebin Han
  • , Bo Luan
  • , Yan Wang
  • , Manhua Chen
  • , Zuyi Yuan
  • , Qian Tong
  • , Yuping Gao
  • , Guoqiang Gu
  • , Xiaodong Li
  • , Yining Yang
  • , Huai Yu
  • , Lijia Ma
  • , Huimin Liu
  • , Maoen Xu
  • , Donghui Zhang
  • , Guang Yang
  • Shuangyin Zhang, Jincheng Han, Maomao Zhang, Haibo Jia, Jingbo Hou, Bo Yu
  • Harbin Medical University
  • Key Lab of the Ministry of Education for Process Control and Efficiency Egineering
  • Sichuan University
  • Shanxi Cardiovascular Hospital
  • The People's Hospital of Liaoning Province
  • Xiamen University
  • The Central Hospital of Wuhan
  • The First Affiliated Hospital of Xi’an Jiaotong University
  • Jilin University
  • Shanxi Bethune Hospital
  • Hebei Medical University
  • China Medical University
  • People's Hospital of Xinjiang Uygur Autonomous Region
  • State Key Laboratory of Frigid Zone Cardiovascular Diseases (SKLFZCD)

科研成果: 期刊稿件文章同行评审

1 引用 (Scopus)

摘要

Background: Optimal plaque preparation in calcified coronary lesions is essential to prevent stent failure. Intravascular lithotripsy (IVL) has shown safety and efficacy in treating severe coronary calcification in prior studies. This study aimed to assess the safety and effectiveness of IVL using domestically produced balloons for the treatment of calcified de novo coronary lesions in Chinese patients. Methods: The VIGOUR trial (NCT05818098) was a prospective, multicenter, single-arm study designed to obtain approval for coronary IVL in patients with severe coronary calcification. The primary endpoint was procedural success. Secondary endpoints included device success, angiographic success, 30-day major adverse cardiovascular events (MACE) incidence, and procedure-related serious complications. An optical coherence tomography (OCT) sub-study was conducted to assess the mechanisms and predictors of calcium modification. Results: A total of 189 patients were enrolled. The primary endpoint was achieved in 93.7% of cases, exceeding the performance goal of 87.0% (p < 0.001). At the secondary endpoints, device success was achieved in 98.9% of patients, and angiographic success in 98.4%. The 30-day MACE incidence was 5.3%, and procedure-related serious complication was 0.5%. 81.9% (59/72) of lesions exhibited OCT-identified multi-plane and longitudinal calcium fractures after IVL. Multivariable analysis revealed that calcium angle was associated with OCT-identified calcium fractures. Conclusions: IVL using domestically produced balloons significantly improves vessel compliance, facilitating successful stent delivery and deployment. This approach proves to be both effective and safe in the Chinese population with severely calcified coronary arteries. OCT-identified calcium fractures post-IVL are more likely in calcified lesions with a larger calcium angle.

源语言英语
页(从-至)3599-3608
页数10
期刊Catheterization and Cardiovascular Interventions
106
7
DOI
出版状态已出版 - 1 12月 2025
已对外发布

学术指纹

探究 'Safety and Efficacy of Intravascular Lithotripsy System: A Prospective, Multicenter Clinical Trial (The VIGOUR Study)' 的科研主题。它们共同构成独一无二的学术指纹。

引用此