TY - JOUR
T1 - Robust dynamic myocardial perfusion CT deconvolution for accurate residue function estimation via adaptive-weighted tensor total variation regularization
T2 - A preclinical study
AU - Zeng, Dong
AU - Gong, Changfei
AU - Bian, Zhaoying
AU - Huang, Jing
AU - Zhang, Xinyu
AU - Zhang, Hua
AU - Lu, Lijun
AU - Niu, Shanzhou
AU - Zhang, Zhang
AU - Liang, Zhengrong
AU - Feng, Qianjin
AU - Chen, Wufan
AU - Ma, Jianhua
N1 - Publisher Copyright:
© 2016 Institute of Physics and Engineering in Medicine.
PY - 2016/10/26
Y1 - 2016/10/26
N2 - Dynamic myocardial perfusion computed tomography (MPCT) is a promising technique for quick diagnosis and risk stratification of coronary artery disease. However, one major drawback of dynamic MPCT imaging is the heavy radiation dose to patients due to its dynamic image acquisition protocol. In this work, to address this issue, we present a robust dynamic MPCT deconvolution algorithm via adaptive-weighted tensor total variation (AwTTV) regularization for accurate residue function estimation with low-mA s data acquisitions. For simplicity, the presented method is termed 'MPD-AwTTV'. More specifically, the gains of the AwTTV regularization over the original tensor total variation regularization are from the anisotropic edge property of the sequential MPCT images. To minimize the associative objective function we propose an efficient iterative optimization strategy with fast convergence rate in the framework of an iterative shrinkage/thresholding algorithm. We validate and evaluate the presented algorithm using both digital XCAT phantom and preclinical porcine data. The preliminary experimental results have demonstrated that the presented MPD-AwTTV deconvolution algorithm can achieve remarkable gains in noise-induced artifact suppression, edge detail preservation, and accurate flow-scaled residue function and MPHM estimation as compared with the other existing deconvolution algorithms in digital phantom studies, and similar gains can be obtained in the porcine data experiment.
AB - Dynamic myocardial perfusion computed tomography (MPCT) is a promising technique for quick diagnosis and risk stratification of coronary artery disease. However, one major drawback of dynamic MPCT imaging is the heavy radiation dose to patients due to its dynamic image acquisition protocol. In this work, to address this issue, we present a robust dynamic MPCT deconvolution algorithm via adaptive-weighted tensor total variation (AwTTV) regularization for accurate residue function estimation with low-mA s data acquisitions. For simplicity, the presented method is termed 'MPD-AwTTV'. More specifically, the gains of the AwTTV regularization over the original tensor total variation regularization are from the anisotropic edge property of the sequential MPCT images. To minimize the associative objective function we propose an efficient iterative optimization strategy with fast convergence rate in the framework of an iterative shrinkage/thresholding algorithm. We validate and evaluate the presented algorithm using both digital XCAT phantom and preclinical porcine data. The preliminary experimental results have demonstrated that the presented MPD-AwTTV deconvolution algorithm can achieve remarkable gains in noise-induced artifact suppression, edge detail preservation, and accurate flow-scaled residue function and MPHM estimation as compared with the other existing deconvolution algorithms in digital phantom studies, and similar gains can be obtained in the porcine data experiment.
KW - adaptive-weighted tensor total variation regularization
KW - deconvolution
KW - flow-scaled residue function
KW - low mA s
KW - myocardial perfusion computed tomography
UR - https://www.scopus.com/pages/publications/84994618720
U2 - 10.1088/0031-9155/61/22/8135
DO - 10.1088/0031-9155/61/22/8135
M3 - 文章
C2 - 27782004
AN - SCOPUS:84994618720
SN - 0031-9155
VL - 61
SP - 8135
EP - 8156
JO - Physics in Medicine and Biology
JF - Physics in Medicine and Biology
IS - 22
ER -