跳到主要导航 跳到搜索 跳到主要内容

Reproducibility of diffusion tensor imaging in normal subjects: An evaluation of different gradient sampling schemes and registration algorithm

  • Xin Liu
  • , Yong Yang
  • , Jubao Sun
  • , Gang Yu
  • , Jin Xu
  • , Chen Niu
  • , Hongjun Tian
  • , Pan Lin
  • Xi'an Jiaotong University
  • Jiangxi University of Finance and Economics
  • Henan University of Science and Technology
  • Central South University
  • Nanjing Fullshare Superconducting Technology Company Limited

科研成果: 期刊稿件文章同行评审

19 引用 (Scopus)

摘要

Introduction: Diffusion tensor imaging (DTI) is very useful for investigating white matter integrity in ageing and neurological disorders; thus, evaluating its reproducibility under different acquisition protocols and analysis methods may assist in the design of clinical studies. Methods: To measure the reproducibility of DTI in normal subjects, this study include (1) depicting the reproducibility of DTI measurements in commonly used regions-of-interest analysis by intraclass correlation coefficient (ICC) and coefficient of variation (CV), (2) evaluating and comparing inter and intrasession test-retest reproducibility, and (3) illustrating the effect of the number of diffusion-encoding directions (NDED) and registration algorithms on measurement reproducibility. Results: DTI measurements exhibit high reproducibility, with overall (430/480) ICC≥0.70, (478/480) within-subject CV (CVws) ≤10.00 % and between-subject CV (CVbs) ranging from 1.32 to 13.63 %. Repeated measures ANOVAs and paired t tests were conducted to compare inter and intrasession reproducibility with different diffusion sampling schemes and registration algorithms. Our results also confirmed that increasing the NDED could improve the accuracy and reproducibility of DTI measurements. In addition, we compared reproducibility indices that were derived using different registration algorithms, and a tensor-based deformable registration yielded the most reproducible results. Finally, we found that increasing the NDED could reduce the difference between the reproducibility of measurement derived using different registration algorithms and between the reproducibility of intersession and intrasession. Conclusion: Our results suggest that the choice of DTI acquisition protocol and post-processing methods can influence the accurate estimation and reproducibility of DTI measurements and should be considered carefully for clinical applications.

源语言英语
页(从-至)497-510
页数14
期刊Neuroradiology
56
6
DOI
出版状态已出版 - 6月 2014

学术指纹

探究 'Reproducibility of diffusion tensor imaging in normal subjects: An evaluation of different gradient sampling schemes and registration algorithm' 的科研主题。它们共同构成独一无二的指纹。

引用此