TY - JOUR
T1 - Quantitative Assessment of Breast Tumor
T2 - Comparison of Four Methods of Positioning Region of Interest for Synthetic Relaxometry and Diffusion Measurement
AU - Gao, Weibo
AU - Yang, Quanxin
AU - Li, Xiaohui
AU - Zhang, Yanyan
AU - He, Tuo
AU - Liang, Wenbin
AU - Wei, Xiaocheng
AU - Yang, Ming
AU - Gao, Bo
AU - Zhang, Guirong
AU - Zhang, Shuqun
N1 - Publisher Copyright:
© 2024 The Association of University Radiologists
PY - 2024/8
Y1 - 2024/8
N2 - Rationale and Objectives: To compare the differences in apparent diffusion coefficient (ADC) and synthetic magnetic resonance (MR) measurements of four region of interest (ROI) placement methods for breast tumor and to investigate their diagnostic performance. Methods: 110 (70 malignant, 40 benign) newly diagnosed breast tumors were evaluated. The patients underwent 3.0 T MR examinations including diffusion-weighted imaging and synthetic MR. Two radiologists independently measured ADCs, T1 relaxation time (T1), T2 relaxation time (T2), and proton density (PD) using four ROI methods: round, square, freehand, and whole-tumor volume (WTV). The interclass correlation coefficient (ICC) was used to assess their measurement reliability. Diagnostic performance was evaluated using multivariate logistic regression analysis and the receiver operating characteristic (ROC) curves. Results: The mean values of all ROI methods showed good or excellent interobserver reproducibility (0.79–0.99) and showed the best diagnostic performance compared to the minimum and maximum values. The square ROI exhibited superior performance in differentiating between benign from malignant breast lesions, followed by the freehand ROI. T2, PD, and ADC values were significantly lower in malignant breast lesions compared to benign ones for all ROI methods (p < 0.05). Multiparameters of T2 + ADC demonstrated the highest AUC values (0.82–0.95), surpassing the diagnostic efficacy of ADC or T2 alone (p < 0.05). Conclusion: ROI placement significantly influences ADC and synthetic MR values measured in breast tumors. Square ROI and mean values showed superior performance in differentiating benign and malignant breast lesions. The multiparameters of T2 + ADC surpassed the diagnostic efficacy of a single parameter.
AB - Rationale and Objectives: To compare the differences in apparent diffusion coefficient (ADC) and synthetic magnetic resonance (MR) measurements of four region of interest (ROI) placement methods for breast tumor and to investigate their diagnostic performance. Methods: 110 (70 malignant, 40 benign) newly diagnosed breast tumors were evaluated. The patients underwent 3.0 T MR examinations including diffusion-weighted imaging and synthetic MR. Two radiologists independently measured ADCs, T1 relaxation time (T1), T2 relaxation time (T2), and proton density (PD) using four ROI methods: round, square, freehand, and whole-tumor volume (WTV). The interclass correlation coefficient (ICC) was used to assess their measurement reliability. Diagnostic performance was evaluated using multivariate logistic regression analysis and the receiver operating characteristic (ROC) curves. Results: The mean values of all ROI methods showed good or excellent interobserver reproducibility (0.79–0.99) and showed the best diagnostic performance compared to the minimum and maximum values. The square ROI exhibited superior performance in differentiating between benign from malignant breast lesions, followed by the freehand ROI. T2, PD, and ADC values were significantly lower in malignant breast lesions compared to benign ones for all ROI methods (p < 0.05). Multiparameters of T2 + ADC demonstrated the highest AUC values (0.82–0.95), surpassing the diagnostic efficacy of ADC or T2 alone (p < 0.05). Conclusion: ROI placement significantly influences ADC and synthetic MR values measured in breast tumors. Square ROI and mean values showed superior performance in differentiating benign and malignant breast lesions. The multiparameters of T2 + ADC surpassed the diagnostic efficacy of a single parameter.
KW - Apparent diffusion coefficient
KW - Breast cancer
KW - Diagnostic performance
KW - Region of interest
KW - Synthetic magnetic resonance
UR - https://www.scopus.com/pages/publications/85188449587
U2 - 10.1016/j.acra.2024.02.045
DO - 10.1016/j.acra.2024.02.045
M3 - 文章
C2 - 38508932
AN - SCOPUS:85188449587
SN - 1076-6332
VL - 31
SP - 3096
EP - 3105
JO - Academic Radiology
JF - Academic Radiology
IS - 8
ER -