TY - JOUR
T1 - Pulsed Ozone–Thermal Cycling in a Plasma Disinfection Strategy
T2 - Achieving Deep-Layer Bacterial Inactivation With Reduced Material Degradation
AU - Ye, Zihao
AU - Zhang, Jishen
AU - Li, Jiaxin
AU - Lu, Xinwei
AU - Zhou, Zhenyang
AU - Zhang, Zizhu
AU - Yu, Weixuan
AU - Liu, Yifan
AU - Wang, Zifeng
AU - Zhang, Hao
AU - Guo, Li
AU - Liu, Dingxin
AU - Rong, Mingzhe
N1 - Publisher Copyright:
© 2026 Wiley-VCH GmbH.
PY - 2026/9
Y1 - 2026/9
N2 - Plasma disinfection faces challenges of residual ozone hazard, material degradation, and insufficient deep-layer bacterial inactivation. We propose a pulsed ozone–thermal cycling strategy using dielectric barrier discharge, alternating ozone generation and hot-air heating within a 40 min cycle. Among three pulsed modes benchmarked against continuous ozone treatment, the optimal high-frequency mode reduced cumulative ozone exposure by 73.2%. It nevertheless produced the greatest deep-layer CFU reduction: 4.18 log10 in three-layer wet textiles versus 1.38 log10 under continuous operation. This is attributed to periodic moisture evaporation and fiber deswelling that reopen pore channels for deeper ozone penetration. The optimal mode simultaneously minimized material degradation and eliminated residual ozone, demonstrating an effective balance among bacterial inactivation efficacy, material preservation, and operational safety.
AB - Plasma disinfection faces challenges of residual ozone hazard, material degradation, and insufficient deep-layer bacterial inactivation. We propose a pulsed ozone–thermal cycling strategy using dielectric barrier discharge, alternating ozone generation and hot-air heating within a 40 min cycle. Among three pulsed modes benchmarked against continuous ozone treatment, the optimal high-frequency mode reduced cumulative ozone exposure by 73.2%. It nevertheless produced the greatest deep-layer CFU reduction: 4.18 log10 in three-layer wet textiles versus 1.38 log10 under continuous operation. This is attributed to periodic moisture evaporation and fiber deswelling that reopen pore channels for deeper ozone penetration. The optimal mode simultaneously minimized material degradation and eliminated residual ozone, demonstrating an effective balance among bacterial inactivation efficacy, material preservation, and operational safety.
KW - deep-layer bacterial inactivation
KW - dielectric barrier discharge
KW - material preservation
KW - plasma disinfection
KW - pulsed ozone–thermal cycling
UR - https://www.scopus.com/pages/publications/105049294727
U2 - 10.1002/ppap.70247
DO - 10.1002/ppap.70247
M3 - 文章
AN - SCOPUS:105049294727
SN - 1612-8850
VL - 23
JO - Plasma Processes and Polymers
JF - Plasma Processes and Polymers
IS - 9
M1 - e70247
ER -