TY - GEN
T1 - Proportional Capacitor Current Feedback Based Active Damping Control for LCL-Filter Converters with Considerable Control Delay
AU - Ma, Zhijun
AU - Zhou, Linyuan
AU - Liu, Jinjun
N1 - Publisher Copyright:
© 2020 IEEE.
PY - 2020/3
Y1 - 2020/3
N2 - LCL filter is widely used in grid connected converters for good harmonic mitigation performance. However, resonance poles of LCL filter challenge the system stability, especially in digital controlled system. Various active damping approaches have been proposed to solve the resonance issue, where the capacitor current based active damping control is an attractive option. In this paper, system stability with capacitor current based active damping control is analyzed with the consideration of digital control delay. A design principle for the active damping compensator is proposed in this paper, where maximum stability margin can be reached for active damping loop. It is shown that capacitor current feedback control with negative proportion gain, instead of positive gain, presents much better performance with considerable control delay. Simulative and experimental results validate the proposed control method.
AB - LCL filter is widely used in grid connected converters for good harmonic mitigation performance. However, resonance poles of LCL filter challenge the system stability, especially in digital controlled system. Various active damping approaches have been proposed to solve the resonance issue, where the capacitor current based active damping control is an attractive option. In this paper, system stability with capacitor current based active damping control is analyzed with the consideration of digital control delay. A design principle for the active damping compensator is proposed in this paper, where maximum stability margin can be reached for active damping loop. It is shown that capacitor current feedback control with negative proportion gain, instead of positive gain, presents much better performance with considerable control delay. Simulative and experimental results validate the proposed control method.
KW - LCL
KW - active damping
KW - capacitor current feedback
UR - https://www.scopus.com/pages/publications/85087759457
U2 - 10.1109/APEC39645.2020.9124121
DO - 10.1109/APEC39645.2020.9124121
M3 - 会议稿件
AN - SCOPUS:85087759457
T3 - Conference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC
SP - 3110
EP - 3114
BT - APEC 2020 - 35th Annual IEEE Applied Power Electronics Conference and Exposition
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 35th Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2020
Y2 - 15 March 2020 through 19 March 2020
ER -