1 引用 (Scopus)

摘要

The minimum hot and cold utilities of heat exchanger networks can be obtained based on the principle of pinch theory. Moreover, reasonable process changes can further reduce hot and cold utilities. Meanwhile, adding heat pumps correctly in a heat exchanger network can reuse the waste heat below the pinch, which reduces both hot and cold utilities and enhances energy utilization. The influence of process changes on hot and cold utilities of heat exchanger networks with heat pumps was analyzed by a graphical method based on the pinch technology. The results show that a process change that originally cannot reduce hot and cold utilities can be transformed into one that can save utilities with the help of heat pumps. Therefore, for heat exchanger networks with heat pumps, whether a process change is profitable also depends on the influence of heat pumps. This work extends the research scope of process change and the acquired results provide theoretical criteria for reasonable process changes.

源语言英语
页(从-至)162-167
页数6
期刊Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities
30
1
DOI
出版状态已出版 - 1 2月 2016

学术指纹

探究 'Process change analysis of heat exchanger networks with heat pumps' 的科研主题。它们共同构成独一无二的学术指纹。

引用此