跳到主要导航 跳到搜索 跳到主要内容

Pressure drop oscillation of steam-water two-phase flow in a helically coiled tube

  • Xi'an Jiaotong University

科研成果: 期刊稿件文章同行评审

48 引用 (Scopus)

摘要

Systematic investigations of pressure drop type oscillations and their thresholds were conducted for steam-water two-phase flow in a uniformly heated, helically coiled tube. Experiments were conducted to obtain the critical conditions for the occurrence of pressure drop type dynamic oscillation in a closed-circulation helically coiled tubing steam generator. The study showed that different locations of the tank which provided a compressible gas volume (called compressible volume for short) corresponded to different oscillation initial boundaries as well as different oscillating amplitudes and time periods. Moving compressible volume from the inlet of the steam generator upstream could dramatically suppress the occurrence of pressure drop oscillation. Also, non-uniform heat flux distribution along the evaporating channel could change oscillating boundaries significantly, especially when higher heat flux was applied to the higher mass quality region. A study of pressure drop oscillation in various steam generator inclinations showed that gravity has little influence upon the oscillating boundaries. Based on the experimental observations, a set of new methods was first proposed to eliminate the occurrence of pressure drop oscillation.

源语言英语
页(从-至)1555-1564
页数10
期刊International Journal of Heat and Mass Transfer
44
8
DOI
出版状态已出版 - 4月 2001

学术指纹

探究 'Pressure drop oscillation of steam-water two-phase flow in a helically coiled tube' 的科研主题。它们共同构成独一无二的指纹。

引用此