TY - GEN
T1 - Power transformer transient modeling considering the effects of on-load tap changer
AU - Ahmad, Asad
AU - Fang, Wanliang
AU - Liu, Jun
AU - Hao, Xudong
N1 - Publisher Copyright:
© 2017 IEEE.
PY - 2017/12/12
Y1 - 2017/12/12
N2 - On-load tap changer (OLTC) is essential in regulating the operation status of power transformers employed in modern power systems. While exploring power flow analysis, electromagnetic and electromechanical simulations by using the on-load tap changer, it is found that inaccuracy problem may occur with the assumption in conventional transformers that tap positions only affect the turns ratio parameter; however, the real transformers specifications, such as the resistances and inductances of windings, also fluctuate with different tap positions. In this paper, a novel inductance matrix model for both single and three phase transformer is proposed, which illustrates that winding resistances and inductances are also varying with the tap positions. Case studies are performed to assess the performance of the proposed transformer model in case of symmetrical and un-symmetrical faults. The novel model is developed using PSCAD/EMTDC software, and the simulation results are compared with traditional transformers. It can be concluded that the parameters of the proposed transformer become more sensitive on the voltage and current during various transient processes. Thus it's vital to provide an applicable attention to the analysis and simulation with the usage of this more accurate mathematical transformer model, which permits us to obtain the more precise behavior of power systems without any risk.
AB - On-load tap changer (OLTC) is essential in regulating the operation status of power transformers employed in modern power systems. While exploring power flow analysis, electromagnetic and electromechanical simulations by using the on-load tap changer, it is found that inaccuracy problem may occur with the assumption in conventional transformers that tap positions only affect the turns ratio parameter; however, the real transformers specifications, such as the resistances and inductances of windings, also fluctuate with different tap positions. In this paper, a novel inductance matrix model for both single and three phase transformer is proposed, which illustrates that winding resistances and inductances are also varying with the tap positions. Case studies are performed to assess the performance of the proposed transformer model in case of symmetrical and un-symmetrical faults. The novel model is developed using PSCAD/EMTDC software, and the simulation results are compared with traditional transformers. It can be concluded that the parameters of the proposed transformer become more sensitive on the voltage and current during various transient processes. Thus it's vital to provide an applicable attention to the analysis and simulation with the usage of this more accurate mathematical transformer model, which permits us to obtain the more precise behavior of power systems without any risk.
KW - Inductance matrix model
KW - On-load tap changer
KW - PSCAD/EMTDC
KW - Symmetrical and un-symmetrical faults
KW - Transformer
UR - https://www.scopus.com/pages/publications/85046849066
U2 - 10.1109/ICEPE-ST.2017.8188947
DO - 10.1109/ICEPE-ST.2017.8188947
M3 - 会议稿件
AN - SCOPUS:85046849066
T3 - ICEPE-ST 2017 - 4th International Conference on Electric Power Equipment- Switching Technology
SP - 766
EP - 770
BT - ICEPE-ST 2017 - 4th International Conference on Electric Power Equipment- Switching Technology
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 4th International Conference on Electric Power Equipment- Switching Technology, ICEPE-ST 2017
Y2 - 22 October 2017 through 25 October 2017
ER -