摘要
In this paper, we propose a novel probe to identify phases in any two-phase flows where one phase is conductive and the other nonconductive. We can further obtain many parameters such as void fraction, bubble velocity, and interfacial area concentration. Compared with the traditional probe, the novel probe has unique advantages that it is less dependent on water conductance or distance between the electrodes, and that the amplitude is bigger between high and low levels. Theoretical analyses showed that the measurement error became higher when water conductance decreases or distance increases, which is consistent with the theoretical analyses. Experimental results showed that the output signal kept constant with salt content of 0-5% and electrode distance of 0-30 mm in tap water. The level difference was up to 6.4 V, resulting in identifying two phases easily. Time traces of phase identification were completely consistent with the flow structures.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 316-320 |
| 页数 | 5 |
| 期刊 | Nuclear Science and Techniques |
| 卷 | 21 |
| 期 | 5 |
| 出版状态 | 已出版 - 20 10月 2010 |
| 已对外发布 | 是 |
学术指纹
探究 'Phase identification by a novel needle-contact capacitance probe in gas-liquid two-phase flows' 的科研主题。它们共同构成独一无二的学术指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver