跳到主要导航 跳到搜索 跳到主要内容

Personal thermal management using portable thermoelectrics for potential building energy saving

  • Dongliang Zhao
  • , Xing Lu
  • , Tianzhu Fan
  • , Yuen Shing Wu
  • , Lun Lou
  • , Qiuwang Wang
  • , Jintu Fan
  • , Ronggui Yang
  • University of Colorado Boulder
  • Xi'an Jiaotong University
  • Cornell University
  • National Renewable Energy Laboratory

科研成果: 期刊稿件 › 文章 › 同行评审

148 引用 (Scopus)

摘要

Heating and cooling of buildings consume approximately 15% of all energy used in the United States. Such a large energy demand is primarily due to heating and cooling of the entire building space to temperature setpoints usually between 21.1 °C (70 °F) and 23.9 °C (75 °F). However, even with such a narrow range of temperature setpoints, more than 20% of the occupants do not feel thermally comfortable due to individual differences (e.g. age, gender, clothing, or physiology). The personal thermal management techniques, which create a local thermal envelope around a human body instead of heating or cooling the entire building space, have the potential to greatly reduce the building energy consumption and to enhance thermal comfort of individuals. In this study, a portable thermoelectric energy conversion unit (TECU) that converts electricity into cooling and heating energy is developed. The TECU supplies cool air (in the cooling mode) or warm air (in the heating mode) to regulate the thermal comfort of a human body. The cool or warm air is supplied through a tree-like rubber tube network that is knitted into a thermoregulatory undergarment. To achieve a cooling/heating target that provides satisfactory thermal comfort, the required cooling/heating power supply from the TECU is determined first while a theoretical model is then developed to guide the design of the TECU. To minimize the TECU weight and make it suitable for portable applications, relationships between weight and thermal resistances of commercial off-the-shelf heat sinks are established first, and a method to find the minimal weight of heat sinks for the TECU is then developed. This methodology is also applicable for other applications where heat sink weight needs to be minimized. The thermal manikin tests demonstrate that 24.6 W of personal cooling power and 18.5 W of personal heating power are achieved by using the TECU.

源语言英语
页(从-至)282-291
页数10
期刊Applied Energy
卷218
DOI
出版状态已出版 - 15 5月 2018

联合国可持续发展目标

此成果有助于实现下列可持续发展目标:

  1. 可持续发展目标 7 - 经济适用的清洁能源
    可持续发展目标 7 经济适用的清洁能源

学术指纹

探究 'Personal thermal management using portable thermoelectrics for potential building energy saving' 的科研主题。它们共同构成独一无二的学术指纹。

引用此