跳到主要导航 跳到搜索 跳到主要内容

Parameters optimization of a parallel-flow heat exchanger with a new type of anti-vibration baffle and coiled wire using Taguchi method

投稿的翻译标题: 基于田口方法的带新型防振折流板和线圈的平行流换热器参数优化
  • Chu lin Yu
  • , Zhi wen Ren
  • , Min Zeng
  • , Min dong Ji
  • Sichuan Dongfang Boiler Group Co., Ltd.
  • Xi'an Jiaotong University

科研成果: 期刊稿件 › 文章 › 同行评审

9 引用 (Scopus)

摘要

This study presents the thermal-hydraulic optimization of the design parameters of a parallel-flow shell-and-tube heat exchanger with a new type of anti-vibration hexagon clamping baffle and equilateral triangle cross-sectioned coiled wire. A periodic flow unit duct with non-staggered tube layout is adopted as the numerical analysis model by Fluent. The Taguchi method is used to explore the influence of five geometric parameters including baffle distance (A), baffle width (B), coil diameter (C), coil pitch (D), and the side length of the equilateral triangle (E). An L18 (35) orthogonal array is chosen to carry out the numerical simulation. The comprehensive thermal-hydraulic performance evaluation criterion (PEC) is set as the optimization goal. The results show that the order of the factor effectiveness for the Nusselt number is E>C>A>D>B, for the flow friction is C>E>A>B>D and for the PEC is C>E>A>B>D. This means that the coil pitch has a great influence while the baffle width and the coil diameter have a trifling effect. Finally, the optimal factor combination for PEC is obtained. The PEC of the optimal combination is 0.19%–1.92% higher than the model with better comprehensive performance among 18 cases for Reynolds number in the range from 14 465 to 32 547.

投稿的翻译标题基于田口方法的带新型防振折流板和线圈的平行流换热器参数优化
源语言英语
页(从-至)676-690
页数15
期刊Journal of Zhejiang University: Science A
卷19
期9
DOI
出版状态已出版 - 1 9月 2018

学术指纹

探究 '基于田口方法的带新型防振折流板和线圈的平行流换热器参数优化' 的科研主题。它们共同构成独一无二的学术指纹。

引用此