TY - GEN
T1 - Operation modes analysis and limitation for diode-assisted buck-boost voltage source inverter with small voltage vector
AU - Zhang, Yan
AU - Liu, Jinjun
AU - Zhou, Sizhan
PY - 2013
Y1 - 2013
N2 - Diode-assisted buck-boost voltage source inverter (VSI) boosts the dc source voltage by introducing a diode-assisted capacitor network. The new topology extends voltage regulation range and avoids extreme duty ratio of switching devices in front boost circuit. As for the unique structure, various pulse-width modulation (PWM) strategies are provided to obtain the maximum linear voltage gain with regard to the chopped intermediate dc-link voltage of the inverter bridge in one switching time period. However, when the inverter supplies inductive or capacitive load with small load power factor, the uni-directional current flow of diode may limit the application of the converter utilizing small voltage vectors for ac output voltage extension. This new operation condition is not expected and has not been discussed before. This paper makes a detailed circuit analysis of the relationship between the undesired operation condition and load power factor. All the theoretical findings are finally verified by simulations and experiments.
AB - Diode-assisted buck-boost voltage source inverter (VSI) boosts the dc source voltage by introducing a diode-assisted capacitor network. The new topology extends voltage regulation range and avoids extreme duty ratio of switching devices in front boost circuit. As for the unique structure, various pulse-width modulation (PWM) strategies are provided to obtain the maximum linear voltage gain with regard to the chopped intermediate dc-link voltage of the inverter bridge in one switching time period. However, when the inverter supplies inductive or capacitive load with small load power factor, the uni-directional current flow of diode may limit the application of the converter utilizing small voltage vectors for ac output voltage extension. This new operation condition is not expected and has not been discussed before. This paper makes a detailed circuit analysis of the relationship between the undesired operation condition and load power factor. All the theoretical findings are finally verified by simulations and experiments.
KW - Dc-link voltage utilization
KW - load power factor
KW - pulse-width modulation
KW - voltage gain
KW - voltage source inverter
UR - https://www.scopus.com/pages/publications/84879372663
U2 - 10.1109/APEC.2013.6520203
DO - 10.1109/APEC.2013.6520203
M3 - 会议稿件
AN - SCOPUS:84879372663
SN - 9781467343541
T3 - Conference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC
SP - 170
EP - 176
BT - 2013 28th Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2013
T2 - 28th Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2013
Y2 - 17 March 2013 through 21 March 2013
ER -