TY - JOUR
T1 - Numerical investigation on startup characteristics of high temperature heat pipe for nuclear reactor
AU - Zhang, Zeqin
AU - Chai, Xiaoming
AU - Wang, Chenglong
AU - Sun, Hao
AU - Zhang, Dalin
AU - Tian, Wenxi
AU - Qiu, Suizheng
AU - Su, G. H.
N1 - Publisher Copyright:
© 2021 Elsevier B.V.
PY - 2021/7
Y1 - 2021/7
N2 - Heat pipe cooled reactor (HPR) has a good adaptability to portable power system, which is popular in recent years. Due to the particularity of alkali-metal working fluid, the deep understanding of startup characteristics of high temperature heat pipe from frozen state is essential for the development of HPRs. In this paper, a three-stage frozen startup model is developed to describe the thermal behavior of heat pipe during the startup process, and the continuum flow in the vapor space is modeled as a one-dimensional compressible flow. A numerical code is carried out, in which the governing equations are discretized by Finite Element Method (FEM), and then the code is used to simulate the startup performance of a NaK heat pipe in HPRs. Numerical results indicate that the heat pipe startup behavior can be well described by the three-stage model. The NaK heat pipe is successfully started with a final consistency temperature of 834 K, although the entire second stage is restricted by the sonic limitation. The startup lasts 1550 s in total, and enters the second and third stage at 230 s and 650 s, respectively. After 1500 s, the maximum Mach number of vapor flow is lower than 0.1, which verifies the rationality of the one-dimensional compressible flow model of vapor. This work could provide a reference for the design and application of HPRs.
AB - Heat pipe cooled reactor (HPR) has a good adaptability to portable power system, which is popular in recent years. Due to the particularity of alkali-metal working fluid, the deep understanding of startup characteristics of high temperature heat pipe from frozen state is essential for the development of HPRs. In this paper, a three-stage frozen startup model is developed to describe the thermal behavior of heat pipe during the startup process, and the continuum flow in the vapor space is modeled as a one-dimensional compressible flow. A numerical code is carried out, in which the governing equations are discretized by Finite Element Method (FEM), and then the code is used to simulate the startup performance of a NaK heat pipe in HPRs. Numerical results indicate that the heat pipe startup behavior can be well described by the three-stage model. The NaK heat pipe is successfully started with a final consistency temperature of 834 K, although the entire second stage is restricted by the sonic limitation. The startup lasts 1550 s in total, and enters the second and third stage at 230 s and 650 s, respectively. After 1500 s, the maximum Mach number of vapor flow is lower than 0.1, which verifies the rationality of the one-dimensional compressible flow model of vapor. This work could provide a reference for the design and application of HPRs.
KW - Alkali metal
KW - Frozen startup
KW - High temperature heat pipe
KW - Numerical investigation
UR - https://www.scopus.com/pages/publications/85103234302
U2 - 10.1016/j.nucengdes.2021.111180
DO - 10.1016/j.nucengdes.2021.111180
M3 - 文章
AN - SCOPUS:85103234302
SN - 0029-5493
VL - 378
JO - Nuclear Engineering and Design
JF - Nuclear Engineering and Design
M1 - 111180
ER -