跳到主要导航 跳到搜索 跳到主要内容

Numerical and experimental investigations on the failure mechanism of the suction valve in the refrigerator compressor under unconventional conditions

  • Xiang Yin
  • , Jianmin Fang
  • , Feng Cao
  • , Zhonghua Chen
  • , Xiaolin Wang
  • Xi'an Jiaotong University
  • Guangzhou Wanbao group co. LTD
  • University of Tasmania

科研成果: 期刊稿件文章同行评审

12 引用 (Scopus)

摘要

The return sample of the reciprocating compressor revealed that the failure of a few suction valves was detected in a transitory time. To deal with this unconventional failure problem, microscopy and failure analysis were conducted and compared with the conventional failure type. The failure assumptions were proposed due to this, and a mathematical model using Fluid-Structure-Interaction (FSI) method was developed to investigate the stress performance and the failure mechanism. Moreover, an accelerated experimental facility was set up to validate the theoretical and numerical results. Results showed that the shear stress was the main reason for the short-time failure, and the head part of the suction valve experienced stress concentration. The failure started from the center of the suction valve's head part and resulted in its fracture at last. The thicker suction valve had the less stress concentration, and the valve head with a less hydraulic diameter had a minor failure possibility during the compression process. It provides reference for the unconventional failure probelme during the practical engineering.

源语言英语
页(从-至)44-51
页数8
期刊International Journal of Refrigeration
117
DOI
出版状态已出版 - 9月 2020

学术指纹

探究 'Numerical and experimental investigations on the failure mechanism of the suction valve in the refrigerator compressor under unconventional conditions' 的科研主题。它们共同构成独一无二的学术指纹。

引用此