跳到主要导航 跳到搜索 跳到主要内容

Numerical analysis on performance and contaminated failures of the miniature split Stirling cryocooler

  • Xi'an Jiaotong University

科研成果: 期刊稿件 › 文章 › 同行评审

18 引用 (Scopus)

摘要

A mathematical model based on thermodynamic theory of variable mass is developed for the split Stirling refrigerator, in which, the whole machine is considered by one-dimensional approach while the processes in the regenerator are simulated by two-dimensional approach. First, the influence of the ideal frost layer distributions on the flow and heat transfer in the regenerator and the performance of the Stirling cryocooler are simulated. Then, the distribution of the contaminated water vapor and its coagulated and deposited process is qualitatively analyzed. Finally, the lifetime of the refrigerator is evaluated based on the calculated data. The results show that when the refrigerator is operated at uniform distribution of the water vapor partial pressure in the regenerator, the cooling capacity is reduced over 10% at about 631 h, and the power consumption of compressor is increased over 20% at about 1168 h. However, for the linear distribution of water vapor partial pressure, the refrigerator can work properly because the frost never reaches the criterion of failure. Also, it is found that when the Stirling cryocooler restarts after a shutdown, the cooling capacity is reduced by 10% once the frost mass is over 7.05 mg, and there is no cooling capacity once the frost mass reaches 41.2 mg.

源语言英语
页(从-至)12-22
页数11
期刊Cryogenics
卷59
DOI
出版状态已出版 - 1月 2014

学术指纹

探究 'Numerical analysis on performance and contaminated failures of the miniature split Stirling cryocooler' 的科研主题。它们共同构成独一无二的学术指纹。

引用此