跳到主要导航 跳到搜索 跳到主要内容

Numerical analysis on heat removal capacity of passive residual heat removal heat exchanger

  • Xi'an Jiaotong University
  • Shanghai Nuclear Engineering Research and Design Institute

科研成果: 期刊稿件文章同行评审

7 引用 (Scopus)

摘要

Thermal-hydraulics characteristics of AP1000 passive residual heat removal heat exchanger (PRHR-HX) at initial operating stage were analyzed based on the porous media model. The data obtained from RELAP5 under the condition of the station blackout was employed as the inlet flow rate and temperature boundary of CFD calculation. The distribution resistances were added into the C-type tube bundle region which was treated as porous zone. Three-dimensional distributions of velocity and temperature in the in-containment refueling water storage tank (IRWST) were calculated by the commercial CFD code FLUENT. The heat transfer between the primary loop side and the IRWST side was calculated by user self-defined function UDF. The results show that the heat transfer capability decreases with the increase of water temperature and a thermal stratification phenomenon in the tank occurs. The present results indicate that the method containing coupled heat transfer from the primary loop side fluid to IRWST side fluid and porous media model is a suitable approach to study the transient thermal-hydraulics of PRHR/IRWST system.

源语言英语
页(从-至)1032-1038
页数7
期刊Yuanzineng Kexue Jishu/Atomic Energy Science and Technology
49
6
DOI
出版状态已出版 - 20 6月 2015

学术指纹

探究 'Numerical analysis on heat removal capacity of passive residual heat removal heat exchanger' 的科研主题。它们共同构成独一无二的学术指纹。

引用此