摘要
Pool boiling and condensing heat transfer of R134a on one plain and three enhanced surfaces are experimentally investigated. The saturation temperature in pool boiling is 6 °C and condensing is 40 °C. The heat flux ranges from 8 to 86 kW/m2. The enhanced tubes include integral-fin, pyramid and re-entrant cavity surface. The outside diameter of test tubes is 19 mm and the length of test section for boiling is 1100 mm and condensing is 1800 mm. Integral-fin tube has lower heat transfer coefficient in boiling and condensing. The deviations of experiment result and Owen or Webb models are within ±10% for integral-fin tube in condensing. Pyramid surface provides quite close heat transfer coefficient with re-entrant cavity surface in pool boiling and condensing at heat flux greater than 70 kW/m2. The heat transfer performances of re-entrant cavity surface tube is the highest among the three enhanced tubes in either pool boiling or condensing at not high heat flux. The heat transfer coefficients can be 1.9-4.8 and 14.8-19.3 times those of a plain tube in pool boiling and condensing respectively. The decreasing rate of heat transfer coefficient for re-entrant cavity surface is also higher than pyramid surface in condensing. Literature survey on nucleate pool boiling and filmwise condensation is also conducted.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 744-754 |
| 页数 | 11 |
| 期刊 | International Journal of Heat and Mass Transfer |
| 卷 | 86 |
| DOI | |
| 出版状态 | 已出版 - 1 7月 2015 |