TY - JOUR
T1 - Noninvasive Pressure Estimation Based on the Subharmonic Response of SonoVue
T2 - Application to Intracranial Blood Pressure Assessment
AU - Qiao, Xiaoyang
AU - Wen, Yu
AU - Yu, Jianjun
AU - Bouakaz, Ayache
AU - Zong, Yujin
AU - Wan, Mingxi
N1 - Publisher Copyright:
© 1986-2012 IEEE.
PY - 2022/3/1
Y1 - 2022/3/1
N2 - Intracranial blood pressure can directly reflect the status of blood vessels in real time. However, it can only be estimated invasively using a microcatheter during craniotomy. Subharmonic-aided pressure estimation (SHAPE) is a promising technique for estimating cardiac pressures but mainly uses Sonazoid, whereas SHAPE using SonoVue is still in the early stages of development. The aim of this study was to optimize transcranial SHAPE using SonoVue by investigating the relationship between subharmonic signals and middle cerebral artery pressure (MCAP) (20-160 mmHg) in vitro. We examined the effect of acoustic output levels (peak negative pressures (PNPs) of 238, 346, and 454 kPa), time in suspension (time from reconstituting the suspension to extracting it: 0-30 min), and exposure to gas-equilibrated saline (3 min, 1 h, or original gas completely replaced by air) on the subharmonic-pressure relationship. A mean subharmonic amplitude over a 0.4 MHz bandwidth was extracted using a 5 MHz 12-cycle pulse. A PNP of 346 kPa elicited the best subharmonic sensitivity for assessing hydrostatic pressures up to 0.24 dB/mmHg, possibly because compression-only behavior no longer occurs at this pressure. Moreover, the expansion force is not large enough to offset the effects of hydrostatic pressure. A linear monotonic relationship between the subharmonic amplitude and hydrostatic pressure was only observed for just prepared SonoVue. Excessive exposure to gas-equilibrated saline also affected the subharmonic-pressure relationship. Therefore, just prepared SonoVue should be used, and the duration of the pressure estimation process should be strictly controlled.
AB - Intracranial blood pressure can directly reflect the status of blood vessels in real time. However, it can only be estimated invasively using a microcatheter during craniotomy. Subharmonic-aided pressure estimation (SHAPE) is a promising technique for estimating cardiac pressures but mainly uses Sonazoid, whereas SHAPE using SonoVue is still in the early stages of development. The aim of this study was to optimize transcranial SHAPE using SonoVue by investigating the relationship between subharmonic signals and middle cerebral artery pressure (MCAP) (20-160 mmHg) in vitro. We examined the effect of acoustic output levels (peak negative pressures (PNPs) of 238, 346, and 454 kPa), time in suspension (time from reconstituting the suspension to extracting it: 0-30 min), and exposure to gas-equilibrated saline (3 min, 1 h, or original gas completely replaced by air) on the subharmonic-pressure relationship. A mean subharmonic amplitude over a 0.4 MHz bandwidth was extracted using a 5 MHz 12-cycle pulse. A PNP of 346 kPa elicited the best subharmonic sensitivity for assessing hydrostatic pressures up to 0.24 dB/mmHg, possibly because compression-only behavior no longer occurs at this pressure. Moreover, the expansion force is not large enough to offset the effects of hydrostatic pressure. A linear monotonic relationship between the subharmonic amplitude and hydrostatic pressure was only observed for just prepared SonoVue. Excessive exposure to gas-equilibrated saline also affected the subharmonic-pressure relationship. Therefore, just prepared SonoVue should be used, and the duration of the pressure estimation process should be strictly controlled.
KW - Middle cerebral artery pressure (MCAP)
KW - subharmonic-aided pressure estimation (SHAPE)
KW - transcranial ultrasound
KW - ultrasound contrast agent
UR - https://www.scopus.com/pages/publications/85122082692
U2 - 10.1109/TUFFC.2021.3138100
DO - 10.1109/TUFFC.2021.3138100
M3 - 文章
C2 - 34941508
AN - SCOPUS:85122082692
SN - 0885-3010
VL - 69
SP - 957
EP - 966
JO - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
JF - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
IS - 3
ER -