TY - JOUR
T1 - Neural specificity of acupuncture stimulation from support vector machine classification analysis
AU - Xue, Ting
AU - Bai, Lijun
AU - Chen, Shangjie
AU - Zhong, Chongguang
AU - Feng, Yuanyuan
AU - Wang, Hu
AU - Liu, Zhenyu
AU - You, Youbo
AU - Cui, Fangyuan
AU - Ren, Yanshuang
AU - Tian, Jie
AU - Liu, Yijun
PY - 2011/9
Y1 - 2011/9
N2 - Acupoint specificity, as a crucial issue in acupuncture neuroimaging studies, is still a controversial topic. Previous studies have generally adopted a block-based general linear model (GLM) approach, which predicts the temporal changes in the blood oxygenation level-dependent signal conforming to the "on-off" specifications. However, this method might become impractical since the precise timing and duration of acupuncture actions cannot be specified a priori. In the current study, we applied a data-driven multivariate classification approach, namely, support vector machine (SVM), to explore the neural specificity of acupuncture at gall bladder 40 (GB40) using kidney 3 (KI3) as a control condition (belonging to different meridians but the same nerve segment). In addition, to verify whether the typical GLM approach is sensitive enough in exploring the neural response patterns evoked by acupuncture, we also employed the GLM method to the same data sets. The SVM analysis detected distinct neural response patterns between GB40 and KI3 - positive predominantly for the GB40, while negative following the KI3. By contrast, group analysis from the GLM showed that acupuncture at these different acupoints can both evoke similar widespread signal decreases in multiple brain regions, and most of these regions were spatially overlapped, mainly distributing in the limbic and subcortical structures. Our findings may provide additional evidence to support the specificity of acupuncture, relevant to its clinical efficacy. Moreover, we also proved that GLM analysis is prone to be susceptible to errors and is not appropriate for detecting neural response patterns evoked by acupuncture stimulation.
AB - Acupoint specificity, as a crucial issue in acupuncture neuroimaging studies, is still a controversial topic. Previous studies have generally adopted a block-based general linear model (GLM) approach, which predicts the temporal changes in the blood oxygenation level-dependent signal conforming to the "on-off" specifications. However, this method might become impractical since the precise timing and duration of acupuncture actions cannot be specified a priori. In the current study, we applied a data-driven multivariate classification approach, namely, support vector machine (SVM), to explore the neural specificity of acupuncture at gall bladder 40 (GB40) using kidney 3 (KI3) as a control condition (belonging to different meridians but the same nerve segment). In addition, to verify whether the typical GLM approach is sensitive enough in exploring the neural response patterns evoked by acupuncture, we also employed the GLM method to the same data sets. The SVM analysis detected distinct neural response patterns between GB40 and KI3 - positive predominantly for the GB40, while negative following the KI3. By contrast, group analysis from the GLM showed that acupuncture at these different acupoints can both evoke similar widespread signal decreases in multiple brain regions, and most of these regions were spatially overlapped, mainly distributing in the limbic and subcortical structures. Our findings may provide additional evidence to support the specificity of acupuncture, relevant to its clinical efficacy. Moreover, we also proved that GLM analysis is prone to be susceptible to errors and is not appropriate for detecting neural response patterns evoked by acupuncture stimulation.
KW - Acupuncture specificity
KW - Functional magnetic resonance imaging (fMRI)
KW - Support vector machine analysis (SVM)
UR - https://www.scopus.com/pages/publications/80051680323
U2 - 10.1016/j.mri.2011.03.003
DO - 10.1016/j.mri.2011.03.003
M3 - 文章
C2 - 21531109
AN - SCOPUS:80051680323
SN - 0730-725X
VL - 29
SP - 943
EP - 950
JO - Magnetic Resonance Imaging
JF - Magnetic Resonance Imaging
IS - 7
ER -