TY - JOUR
T1 - Near-field high-resolution coded aperture gamma-ray imaging with separable masks
AU - Sun, Shifeng
AU - Liu, Yang
AU - Ouyang, Xiaoping
N1 - Publisher Copyright:
© 2019 Elsevier B.V.
PY - 2020/1/21
Y1 - 2020/1/21
N2 - A coded aperture gamma camera based on a novel imaging model which decomposes the mask projections as a superposition of two separable functions was proposed for near-field high-resolution gamma-ray imaging. In this system, a separable mask was used to reduce the complexity of calibration and the computational burden of image reconstruction. The performance of the system was investigated by using GEANT4 Monte Carlo simulations. The quality of the reconstructed image depends on both mask thickness and gamma-ray energy. High quality reconstructed images of different energy planar sources were obtained. When the aperture diameter was 2.0 mm and the mask thickness was 20.0 mm, the estimated spatial resolution (full width at half maximum) were 2.1, 3.2, 8.4 and 10.2 mm for 140, 356, 662 and 1170 keV photons, respectively. The analysis results of reconstructed images indicate that, unlike using the cross correlation method, the performance of the system was not affected by the aperture collimation effects. The mask and anti-mask technique can help to increase the quality of reconstructed images when the counting statistics were large.
AB - A coded aperture gamma camera based on a novel imaging model which decomposes the mask projections as a superposition of two separable functions was proposed for near-field high-resolution gamma-ray imaging. In this system, a separable mask was used to reduce the complexity of calibration and the computational burden of image reconstruction. The performance of the system was investigated by using GEANT4 Monte Carlo simulations. The quality of the reconstructed image depends on both mask thickness and gamma-ray energy. High quality reconstructed images of different energy planar sources were obtained. When the aperture diameter was 2.0 mm and the mask thickness was 20.0 mm, the estimated spatial resolution (full width at half maximum) were 2.1, 3.2, 8.4 and 10.2 mm for 140, 356, 662 and 1170 keV photons, respectively. The analysis results of reconstructed images indicate that, unlike using the cross correlation method, the performance of the system was not affected by the aperture collimation effects. The mask and anti-mask technique can help to increase the quality of reconstructed images when the counting statistics were large.
KW - Coded aperture
KW - Gamma-ray imaging
KW - Image reconstruction
KW - Monte Carlo simulation
UR - https://www.scopus.com/pages/publications/85073977870
U2 - 10.1016/j.nima.2019.163001
DO - 10.1016/j.nima.2019.163001
M3 - 文章
AN - SCOPUS:85073977870
SN - 0168-9002
VL - 951
JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
M1 - 163001
ER -