跳到主要导航 跳到搜索 跳到主要内容

Multi-axis dynamic displacement measurement based on a strain shunt structure

  • University of Oxford

科研成果: 期刊稿件文章同行评审

5 引用 (Scopus)

摘要

Transient gap or crack width monitoring is essential for structural health monitoring and failure analysis of large civil structures. In this paper, an innovative multi-axis displacement sensor, which utilises metal foil strain gauges on a strain shunt structure, has been proposed. This displacement sensor has the advantages inherited from metal foil strain sensing, such as low cost, high precision, fast dynamic response and low power consumption, and can also measure displacement in two axes independently. The working principles and sensitivity are derived theoretically from key geometrical parameters of the shunt structure, and the linear response of strain values to the given displacement of two translational axes has been demonstrated experimentally. Furthermore, modal response, stress concentration, optimal gauges installation positions and bending deformation due to moment of the third axis are studied numerically.

源语言英语
页(从-至)62-74
页数13
期刊Sensors and Actuators A: Physical
272
DOI
出版状态已出版 - 1 4月 2018