TY - JOUR
T1 - Multi-angle Scheimpflug projection 3D microscope
T2 - Design, calibration, and three-dimensional reconstruction
AU - Deng, Huiwen
AU - Liu, Yong
AU - Zhang, Guofeng
AU - Qu, Xing
AU - Ge, Lingyu
AU - Yang, Shuming
N1 - Publisher Copyright:
© 2023 Elsevier Ltd
PY - 2023/11/30
Y1 - 2023/11/30
N2 - 3D measurement of complex micro-structures has becoming increasingly important for precision manufacturing. In this paper, a multi-angle Scheimpflug projection 3D microscope (MASP-3DM) is proposed, and the detailed design procedure is given. The system deployed four Scheimpflug projections and one telecentric imaging to overcome the shortcomings of limited depth of field (DOF), occlusion and reflection. Then, an improved and practical system calibration method is proposed, which utilizes pinhole projection model to calibrate the telecentric imaging. Meanwhile, local homography is combined with perspective-n-point (PnP) strategy to improve the calibration accuracy. Further, a point-cloud registration error correction model is established to achieve complete and high-precision measurement. The experimental results indicate that the re-projection error is within ±0.5μm and the registration error is less than 2μm for system calibration, the maximum of mean deviation, measurement bias, standard deviation, and type A uncertainty are respectively less than 3μm, 7μm, 4μm, and 1μm for 3D measurement, within the 10(H)mm×50(W)mm×40(D)mm volume.
AB - 3D measurement of complex micro-structures has becoming increasingly important for precision manufacturing. In this paper, a multi-angle Scheimpflug projection 3D microscope (MASP-3DM) is proposed, and the detailed design procedure is given. The system deployed four Scheimpflug projections and one telecentric imaging to overcome the shortcomings of limited depth of field (DOF), occlusion and reflection. Then, an improved and practical system calibration method is proposed, which utilizes pinhole projection model to calibrate the telecentric imaging. Meanwhile, local homography is combined with perspective-n-point (PnP) strategy to improve the calibration accuracy. Further, a point-cloud registration error correction model is established to achieve complete and high-precision measurement. The experimental results indicate that the re-projection error is within ±0.5μm and the registration error is less than 2μm for system calibration, the maximum of mean deviation, measurement bias, standard deviation, and type A uncertainty are respectively less than 3μm, 7μm, 4μm, and 1μm for 3D measurement, within the 10(H)mm×50(W)mm×40(D)mm volume.
KW - 3D microscopy
KW - 3D reconstruction
KW - Calibration
KW - Instrumentation and measurement
KW - Phase measurement
UR - https://www.scopus.com/pages/publications/85173625503
U2 - 10.1016/j.measurement.2023.113609
DO - 10.1016/j.measurement.2023.113609
M3 - 文章
AN - SCOPUS:85173625503
SN - 0263-2241
VL - 222
JO - Measurement: Journal of the International Measurement Confederation
JF - Measurement: Journal of the International Measurement Confederation
M1 - 113609
ER -