跳到主要导航 跳到搜索 跳到主要内容

Monte Carlo based operational and shutdown dose rate calculations of HT-7U tokamak

  • Yixue Chen
  • , Yican Wu
  • , Qunying Huang
  • Karlsruhe Institute of Technology
  • CAS - Institute of Plasma Physics

科研成果: 期刊稿件文章同行评审

14 引用 (Scopus)

摘要

The superconducting tokamak HT-7U will perform D-D plasma experiments and the production rate of 2.45 MeV neutrons will achieve the level of 10 15n/s. The dose rates during operation and after shutdown of HT-7U have been calculated based on a detailed three-dimensional model with the Monte Carlo code MCNP-4C, the inventory code FISPACT and the FENDL-2 nuclear data library. The so-called R2S method was used to perform the shutdown dose rate analyses. The results confirm that personnel access into the tokamak hall must be prohibited during operation. In addition the results show that the dose rate level near the outer wall of the tokamak hall slightly exceeds the dose limit. Additional shielding may be required. The shutdown dose rates of various experimental campaigns have been calculated and the waiting times for personnel access into the hall have been assessed. The results indicate that the in-vessel components of HT-7U will be considerably activated by neutrons and the shutdown dose rate level around the machine after long D-D plasma discharges is serious within a certain range of cooling time regarding the maintenance work.

源语言英语
页(从-至)155-162
页数8
期刊Fusion Engineering and Design
70
2
DOI
出版状态已出版 - 2月 2004

学术指纹

探究 'Monte Carlo based operational and shutdown dose rate calculations of HT-7U tokamak' 的科研主题。它们共同构成独一无二的学术指纹。

引用此